Ambulatory blood pressure monitoring, generally considered well-tolerated, can occasionally be associated with significant local complications such as arm pain and rash.
Answers are grounded in this paper and cite their sources.
ABPM may rarely cause local complications; this case report leaves open incidence and risk factors.
Letters15 September 1994A Complication of Ambulatory Blood Pressure MonitoringM. D. Baetz, MD, George Pylypchuk, MD, and Marilyn Baetz, MDM. D. Baetz, MDSearch for more papers by this author, George Pylypchuk, MDSearch for more papers by this author, and Marilyn Baetz, MDSearch for more papers by this authorAuthor, Article, and Disclosure Informationhttps://doi.org/10.7326/0003-4819-121-6-199409150-00016 SectionsAboutFull TextPDF ToolsAdd to favoritesDownload CitationsTrack CitationsPermissions ShareFacebookTwitterLinkedInRedditEmail TO THE EDITOR:A recent review noted the rapid increase in the use of ambulatory blood pressure monitoring [1]. This procedure is considered to be well tolerated and is associated with few complications [2]. We report a case involving significant complications from such monitoring.A 46-year-old woman was placed on 24-hour ambulatory blood pressure monitoring. Measurements were set at 20-minute intervals during the day and hourly at night. She had no history of diabetes, bleeding disorders, or easy bruisability. After 12 hours on the machine, the patient noted that she had pain in her arm and a rash on her ...References1. Appel LF, Stason WB. Ambulatory blood pressure monitoring in the diagnosis and management of hypertension. Ann Intern Med. 1993; 118:867-83. Google Scholar2. White WB, Manoor GA. Ambulatory blood pressure monitoring. Current Opinion in Nephrology and Hypertension. 1993; 2:928-34. Google Scholar3. White WB. The Rumpel-Leede sign associated with a non-invasive ambulatory blood pressure monitor (Letter). JAMA. 1985; 253:1724. Google Scholar4. Creevy PA, Burris JF, Mroczek WJ. Phlebitis associated with noninvasive 24-hour ambulatory blood pressure monitor (Letter). JAMA. 1985; 254:2411. Google Scholar Author, Article, and Disclosure InformationAffiliations: PreviousarticleNextarticle Advertisement FiguresReferencesRelatedDetails Metrics Cited ByAnesthetic Concerns During Surgical Excision of Intracranial Arteriovenous MalformationsMonitoring Devices in the Intensive Care UnitNIBP Monitoring as a Cause for Intraoperative Hypotension and Postoperative Monoparesis in a Patient Undergoing Lumbar LaminectomyComparison of Ecchymosis Rates With Measurement of Automated and Manual Blood Pressures in Patients Receiving Eptifibatide TherapySpecial anesthetic considerations for stereotactic radiosurgery in childrenSide effects of ambulatory blood pressure monitoringAcute Biceps Compartment Syndrome Associated with the Use of a Noninvasive Blood Pressure MonitorAmbulatory Blood Pressure Monitoring in the Diagnosis of Hypertension 15 September 1994Volume 121, Issue 6Page: 468-469KeywordsBlood pressureCapillariesHematologic testsHemorrhageRashesSystolic pressure Issue Published: 15 September 1994 CopyrightCopyright © 1994 by American College of Physicians. All Rights Reserved.PDF DownloadLoading ...
No takes yet. Share an insight, caveat, or question.
Marilyn Baetz (1994) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: