Key result
Higher work intensity during active recovery from impulse-like exercise induced a shorter initial time delay (6 seconds vs 7 seconds) in the mediation of ventilation by arterial carbon dioxide.
Why the study?
Does higher work intensity during recovery from impulse-like exercise shorten the time delay in the mediation of ventilation by arterial CO2 pressure in healthy males?
Does higher work intensity during recovery from impulse-like exercise shorten the time delay in the mediation of ventilation by arterial CO2 pressure in healthy males?
Higher work intensity during active recovery from impulse-like exercise induces a shorter time delay in the mediation of ventilation by arterial CO2 pressure.
Answers are grounded in this paper and cite their sources.
May inform ventilatory control models during recovery; leaves open relevance to patients with cardiopulmonary disease.
Time delay in the mediation of ventilation (V(.)E) by arterial CO(2) pressure (PaCO(2)) was studied during recovery from short impulse-like exercises with different work loads of recovery. Subjects performed two tests including 10-s impulse like exercise with work load of 200 watts and 15-min recovery with 25 watts in test one and 50 watts in test two. V(.)E, end tidal CO(2) pressure (PETCO(2)) and heart rate (HR) were measured continuously during rest, warming up, exercise and recovery. PaCO(2) was estimated from PETCO(2) and tidal volume (V(T)). Results showed that predicted arterial CO(2) pressure (PaCO(2 pre)) increased during recovery in both tests. In both tests, V(.)E increased and peaked at the end of exercise. V(.)E decreased in the first few seconds of recovery but started to increase again. The highest correlation coefficient between PaCO(2 pre) and V(.)E was obtained in the time delay of 7 s (r=0.854) in test one and in time delays of 6 s (r=0.451) and 31 s (r=0.567) in test two. HR was significantly higher in test two than in test one. These results indicate that PaCO(2 pre) drives V(.)E with a time delay and that higher work intensity induces a shorter time delay.
No takes yet. Share an insight, caveat, or question.
Afroundeh et al. (2014) studied Healthy (n=8). Active recovery with 50 watts work load vs. Active recovery with 25 watts work load was evaluated on Time delay for highest cross-correlation between predicted arterial CO2 pressure and ventilation during recovery. Higher work intensity during active recovery from impulse-like exercise induced a shorter initial time delay (6 seconds vs 7 seconds) in the mediation of ventilation by arterial carbon dioxide.
Synapse has enriched 10 related papers. Consider them for comparative context: