Key result
A novel semi-automated 3D technique for quantifying pericoronary epicardial adipose tissue radiodensity demonstrated excellent reproducibility, with intraobserver and interobserver ICCs of 0.99.
Why the study?
The study aimed to investigate a novel semi-automated 3D quantification method for measuring pericoronary epicardial adipose tissue radiodensity.
Observational (n=24)
No
A novel, semi-automated 3D technique for quantifying pericoronary epicardial adipose tissue radiodensity on cardiac CT demonstrates excellent intra- and interobserver reproducibility.
Novel 3D PCATrd quantification feasible in small retrospective cohort; leaves open its prognostic utility pending larger validation studies.
Objectives This study aimed to investigate a novel semi-automated three-dimensional (3D) quantification of the pericoronary epicardial adipose tissue radiodensity (PCATrd). Methods Twenty-four subjects who previously underwent contrast-enhanced cardiac CT scans were retrospectively identified. The PCATrd was measured in ITK-SNAP imaging software using a Hounsfield unit threshold (−190,-3) to define epicardial adipose tissue (EAT). A spherical 3D brush tool was used on multiplanar reformatted images to segment the PCAT. We defined the PCATrd as EAT within the orthogonal distance from the coronary artery (CA) outer wall equal to the diameter of the corresponding CA segment. The segmentation followed the path of major CAs. Additionally, the PCAT of twenty-five calcified segments were segmented. Reliability of this novel segmentation protocol was assessed using Dice Similarity Coefficients (DSCs) and intraclass coefficient (ICC). Results The segmentation reproducibility for the PCAT was high, with intraobserver DSC 0.86±0.04 for the full length of major CAs and 0.85±0.07 for the calcified segments, and interobserver DSC 0.84±0.04 for the full length of major CAs and 0.83±0.05 for the calcified segments. The reproducibility of the PCATrd value assessed by ICC was also excellent, with intraobserver ICC 0.99 for the full length of major CAs and 0.99 for the calcified segments, and interobserver ICC 0.99 for the full length of major CAs and 0.99 for the calcified segments. Conclusions Our novel 3D PCATrd quantification technique is reliable and reproducible. The availability of the open source software and detailed image analysis pipeline will enable reliable replications and broad uptake of our technique. Key points We have produced a novel, semiautomated technique to comprehensively quantify pericoronary epicardial adipose tissue radiodensity (PCATrd) which is a novel imaging biomarker of coronary inflammation. Our method of PCAT segmentation has excellent reproducibility. We use open source software and provide detailed image analysis pipeline of quantifying PCATrd, which will allow easy replication and broad uptake of our technique.
No takes yet. Share an insight, caveat, or question.
Xu et al. (2020) conducted an observational in Coronary artery disease (n=24). 3D quantification of pericoronary epicardial adipose tissue radiodensity (PCATrd) was evaluated on Intraobserver and interobserver reproducibility (Intraclass correlation coefficient) (ICC 0.99). A novel semi-automated 3D technique for quantifying pericoronary epicardial adipose tissue radiodensity demonstrated excellent reproducibility, with intraobserver and interobserver ICCs of 0.99.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: