Answers are grounded in this paper and cite their sources.
concentration is maintained above the MIC. Hence time period during which AUC was more than MIC is more important than peak drug concentration (Fig. s mentioned, the vancomycin AUC range has a narrow therapeutic effect. The AUC-guided dosing regimen is more appropriate for vancomycin monitoring. The Bayesian software program-based approach to monitoring AUC is the preferred one. This software is based on the pharmacokinetic (PK) model, which works on the bases of the huge data of vancomycin concentration as the Bayesian prior. It optimizes the vancomycin delivery based on one or two samples of vancomycin concentration. Two samples are preferred; among them, one should be collected after 1-2 hours of vancomycin infusion and the second at the end of the dosing interval. When the trough level is measured, dIscussIon Vancomycin is a rapidly acting drug and gets eliminated from the body by glomerular filtration in the kidney. Measuring vancomycin serum level is useful in deciding the drug efficacy, clearance, and dosing regimen in an individual patient.
No takes yet. Share an insight, caveat, or question.
Shenoy et al. (2023) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: