Key result
A 3-dimensional free-breathing cardiovascular MR technique quantified respiratory variation in LVEDV as 5.9% in under 5 minutes, with no significant difference compared to 9- or 25-minute scans.
Absolute Event Rate: 5.9% vs 5.3%
p-value: p=0.64
A novel 3D free-breathing cardiovascular MR technique enables high spatial-resolution quantification of respiratory variation in LVEDV in under 5 minutes.
May enable respiratory-resolved LV volumetry in free-breathing CMR; leaves open validation in patients and clinical utility.
PURPOSE: To develop a 3-dimensional free-breathing cardiovascular MR technique for quantifying the variation in left ventricular end-diastolic volume (LVEDV) during the respiratory cycle. METHODS: A 3-dimensional radial trajectory with double golden-angle ordering was used for free-running data acquisition during free breathing in healthy volunteers (N = 8). A respiratory self-gating signal was extracted from the center of k-space, and data were retrospectively binned into eight respiratory phases in end-diastole. Three-dimensional image volumes with 2-mm isotropic spatial resolution were reconstructed with conjugate-gradient sensitivity encoding for acquisition durations of 4.5, 9, and 25 min. The LVEDV was manually segmented for each respiratory phase and acquisition duration. RESULTS: Respiratory-induced variation expressed as minimum LVEDV (during mid-inspiration) relative to maximum LVEDV (during mid-expiration) was 5.9 ± 0.3% for 4.5 min, 5.3 ± 0.4% for 9 min (P = 0.64 versus 4.5 min), and 5.0 ± 0.4% for 25 min (P = 0.25 versus 4.5 min, and P = 1.00 versus 9 min). CONCLUSIONS: The proposed technique enables high spatial-resolution quantification of the respiratory variation in LVEDV during free breathing in under 5 min, and was found to be 5 to 6% for healthy volunteers. Magn Reson Med 79:2693-2701, 2018.
No takes yet. Share an insight, caveat, or question.
Holst et al. (2017) studied Healthy volunteers (n=8). 3-dimensional free-breathing cardiovascular MR technique (4.5 min acquisition) vs. 9 min and 25 min acquisitions was evaluated on Respiratory-induced variation in LVEDV (minimum relative to maximum) (p=0.64). A 3-dimensional free-breathing cardiovascular MR technique quantified respiratory variation in LVEDV as 5.9% in under 5 minutes, with no significant difference compared to 9- or 25-minute scans.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: