Answers are grounded in this paper and cite their sources.
Simultaneously oscillated 48-μ m and 57-μ m CH 3 OD lasers pumped by a 9R(8) CO 2 laser have been developed as optical sources of interferometer and polarimeter for fusion plasma diagnostics. The objective of this paper is to present a method for stabilizing the two-color far-infrared (FIR) laser outputs. A stable FIR laser requires a stable pump CO 2 laser and a prevention of a back reflection from the FIR laser cavity. The frequency of the pump CO 2 laser has been stabilized by an external Stark-cell modulation. The back reflection has been reduced by an optical isolator using a quarter-wave plate and an absorbing thin-film reflector. The two-color FIR laser outputs have been stabilized by controlling the cavity length. As a result of these measures, we have achieved output stabilities of ± 1.2%/h at the 48-μ m laser and ± 1.3%/h at the 57-μ m laser.
No takes yet. Share an insight, caveat, or question.
Nakayama et al. (2015) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: