Key result
The No-React BioConduit composite stentless aortic valved conduit provided an overall 10-year survival of 51% and 88% freedom from device-related mortality in high-risk patients undergoing aortic root replacement.
Cohort (n=67)
No
The totally biological No-React BioConduit provides excellent long-term clinical results and resists structural deterioration up to 10 years for aortic root replacement.
May inform conduit selection in high-risk aortic root replacement; extends observational durability data but leaves randomized comparisons open.
OBJECTIVES: To retrospectively analyze the clinical outcome of a totally biological composite stentless aortic valved conduit (No-React® BioConduit) implanted using the Bentall procedure over ten years in a single centre. METHODS: Between 27/10/99 and 19/01/08, the No-React® BioConduit composite graft was implanted in 67 patients. Data on these patients were collected from the in-hospital database, from patient notes and from questionnaires. A cohort of patients had 2D-echocardiogram with an average of 4.3 ± 0.45 years post-operatively to evaluate valve function, calcification, and the diameter of the conduit. RESULTS: Implantation in 67 patients represented a follow-up of 371.3 patient-year. Males were 60% of the operated population, with a mean age of 67.9 ± 1.3 years (range 34.1-83.8 years), 21 of them below the age of 65. After a mean follow-up of 7.1 ± 0.3 years (range of 2.2-10.5 years), more than 50% of the survivors were in NYHA I/II and more than 60% of the survivors were angina-free (CCS 0). The overall 10-year survival following replacement of the aortic valve and root was 51%. During this period, 88% of patients were free from valved-conduit related complications leading to mortality. Post-operative echocardiography studies showed no evidence of stenosis, dilatation, calcification or thrombosis. Importantly, during the 10-year follow-up period no failures of the valved conduit were reported, suggesting that the tissue of the conduit does not structurally change (histology of one explant showed normal cusp and conduit). CONCLUSIONS: The No-React® BioConduit composite stentless aortic valved conduit provides excellent long-term clinical results for aortic root replacement with few prosthesis-related complications in the first post-operative decade.
No takes yet. Share an insight, caveat, or question.
Galiñanes et al. (2011) conducted a cohort in Aortic valve and root pathology (n=67). No-React BioConduit composite stentless aortic valved conduit was evaluated on Overall 10-year survival. The No-React BioConduit composite stentless aortic valved conduit provided an overall 10-year survival of 51% and 88% freedom from device-related mortality in high-risk patients undergoing aortic root replacement.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: