Answers are grounded in this paper and cite their sources.
We present a wide bandwidth, compressed sensing based nonuniform sampling (NUS) system with a custom sample-and-hold chip designed to take advantage of a low average sampling rate. By sampling signals nonuniformly, the average sample rate can be more than a magnitude lower than the Nyquist rate, provided that these signals have a relatively low information content as measured by the sparsity of their spectrum. The hardware design combines a wideband Indium-Phosphide heterojunction bipolar transistor sample-and-hold with a commercial off-the-shelf analog-to-digital converter to digitize an 800 MHz to 2 GHz band (having 100 MHz of noncontiguous spectral content) at an average sample rate of 236 Ms/s. Signal reconstruction is performed via a nonlinear compressed sensing algorithm, and the challenges of developing an efficient implementation are discussed. The NUS system is a general purpose digital receiver. As an example of its real signal capabilities, measured bit-error-rate data for a GSM channel is presented, and comparisons to a conventional wideband 4.4 Gs/s ADC are made.
No takes yet. Share an insight, caveat, or question.
Wakin et al. (2012) studied this question.