Key result
MRI-based measurements of brown adipose tissue in infants demonstrated good interscan repeatability for volume (ICC 0.92, p=0.001) and fat signal fraction (ICC 0.93, p<0.001).
Why the study?
The role of brown adipose tissue in infant metabolism remains poorly understood because PET/CT imaging is not suitable for infants.
Does 3-T MRI provide reliable measurements of brown adipose tissue in nonsedated infants?
Observational (n=10)
Does 3-T MRI provide reliable measurements of brown adipose tissue in nonsedated infants?
Effect estimate: ICC 0.92 for volume, ICC 0.93 for FSF
p-value: p=0.001 for volume, <0.001 for FSF
MRI is a reliable and quantitative method for measuring brown adipose tissue volume in infants.
MRI enables noninvasive infant BAT assessment; leaves open its metabolic role pending validation.
OBJECTIVE: The role of brown adipose tissue (BAT) in infant metabolism remains poorly understood, primarily because of the inherent limitation of positron emission tomography/computed tomography imaging to measure BAT, which is not suitable for infants. The aims of this method development study were to assess the feasibility, intra-rater reliability, interscan repeatability, and physiological relevance of measuring BAT in infants using magnetic resonance imaging (MRI). METHODS: A total of 10 nonsedated infants (mean age, 22.6 [1.3] days old) completed two 3-T MRI exams using chemical-shift-encoded water-fat scans 6.2 (2.8) days apart. Candidate BAT voxels in the supraclavicular region were identified based on fat signal fraction (FSF). The volumes of BAT depots were manually traced, and FSF was calculated. Whole-body fat mass was determined using dual-energy x-ray absorptiometry. RESULTS: , and the mean FSF was 16.41% (SD 3.3%). Intra-rater analysis showed good reliability with no systemic bias (proportional bias for volume: p = 0.19; FSF: p = 0.30). Test-retest for interscan repeatability was good (intraclass correlation coefficients for volume: 0.92, p = 0.001 and intraclass correlation coefficients for FSF: 0.93, p < 0.001). FSF was inversely related to fat-free mass (r = -0.69, p = 0.03). CONCLUSIONS: This method development study supports the use of MRI to obtain reliable and quantitative measurements of BAT volume in infants.
No takes yet. Share an insight, caveat, or question.
Flanagan et al. (2021) conducted an observational in Healthy infants (n=10). 3-T MRI using chemical-shift-encoded water-fat scans was evaluated on Interscan repeatability for brown adipose tissue volume and fat signal fraction (ICC 0.92 for volume, ICC 0.93 for FSF, p=0.001 for volume, <0.001 for FSF). MRI-based measurements of brown adipose tissue in infants demonstrated good interscan repeatability for volume (ICC 0.92, p=0.001) and fat signal fraction (ICC 0.93, p<0.001).