Answers are grounded in this paper and cite their sources.
The novel insight of this study is to analyze peristaltic motion in the presence of a catheter during oesophageal manometry. The oesophageal manometry test has the zenith rank for the diagnosis and treatment of the patients suffering from oesophageal motility disorders. We derive the analytical results for pressure distribution along the oesophageal axis, axial and radial velocities and pressure-rise per wavelength. We further analyze the impact of catheter thickness on the derived results by plotting graphs. We observe that if the catheter is thicker diametrically, the pressure to drag the bolus is more. This qualitative observation validates the experimental observation reported in medical journals. It is also observed that axial and radial velocities reduce in the presence of a catheter in oesophagus but pressure gradient retarding the flow enhances. Additionally, we observe that the catheter wall experiences higher shear stress compared to the oesophageal wall, indicating that axial velocity changes more rapidly near the catheter wall than near the oesophageal wall.
No takes yet. Share an insight, caveat, or question.
Singh et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: