Key result
A biotinylated RNA probe detected 0.1 ng of viral DNA or 10 PFU of infectious virus, demonstrating sensitivity and specificity comparable to a 32P-radiolabeled RNA probe for detecting porcine parvovirus.
Nonradioactive slot blot hybridization using a biotinylated RNA probe offers a sensitive and specific alternative to radiolabeled probes for detecting porcine parvovirus.
May support safer veterinary parvovirus diagnostics; leaves open validation before routine clinical use.
Nonradioactive slot blot hybridization assays were established for the detection of porcine parvovirus (PPV), using either a digoxigenin-labeled DNA probe or a biotinylated RNA probe. All probes were prepared from a 3.3-kb Pst1-EcoR1 DNA fragment of the NADL8 isolate of PPV. The sensitivity and specificity of the probes in a slot blot system were evaluated in comparison with a 32P-radiolabeled RNA probe. Using an anti-digoxigenin alkaline phosphatase detection system, at least 1 ng of viral replicative form (RF) DNA, or the equivalent of 100 plaque forming units (PFU) of infectious virus, could be detected by the digoxigenin-labeled DNA probe. When the biotinylated RNA probe and a strepavidin-alkaline phosphatase detection system were employed, 0.1 ng of RF DNA, or the equivalent of 10 PFU of infectious virus, were detected, comparable to the sensitivity of the 32P-radiolabeled RNA probe. Hybridization was not observed with control DNA samples extracted from swine testicle cells, porcine kidney (PK-15) cells, uninfected mixed swine fetal tissue, or from an unrelated DNA virus (pseudorabies virus) infected PK-15 cells. Different isolates of PPV, namely NADL8, NADL2, KBSH, and Kresse, reacted on an equimolar basis in sensitivity and specificity to the biotinlyated probe. Extraction of DNA directly on the filter membrane (direct filter hybridization) was employed in an attempt to reduce processing time by eliminating DNA extraction steps. Direct filter hybridization was indeed less time consuming; it was also comparable in sensitivity and specificity to those methods employing purified DNA.
No takes yet. Share an insight, caveat, or question.
Oraveerakul et al. (1990) studied Porcine parvovirus (PPV) detection. Nonradioactive slot blot hybridization assays (biotinylated RNA or digoxigenin-labeled DNA probes) vs. 32P-radiolabeled RNA probe was evaluated on Sensitivity and specificity of viral DNA detection. A biotinylated RNA probe detected 0.1 ng of viral DNA or 10 PFU of infectious virus, demonstrating sensitivity and specificity comparable to a 32P-radiolabeled RNA probe for detecting porcine parvovirus.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: