Key result
A standardized antibiotic prophylaxis protocol for cardiac implantable electronic device implantation was associated with an early infection incidence of 1.9% (12 of 639 cases).
Why the study?
Early infection of cardiac implantable electronic devices is a growing health challenge, prompting an examination of the effectiveness of antibiotic prophylaxis and treatment of early infection.
Does a protocol of IV ceftriaxone, gentamicin pocket irrigation, and oral amoxicillin/clavulanate prevent early infection in patients undergoing CIED implantation?
Observational (n=639)
No
Does a protocol of IV ceftriaxone, gentamicin pocket irrigation, and oral amoxicillin/clavulanate prevent early infection in patients undergoing CIED implantation?
A protocol of IV ceftriaxone, gentamicin pocket irrigation, and oral amoxicillin/clavulanate resulted in a low 1.9% incidence of early CIED infection.
Supports this prophylaxis regimen in CIED implantation; hypothesis-generating and requires randomized trials before practice change.
BACKGROUND: Cardiac implantable electronic devices - PM, ICD, and CRTs- are well-proven life-sustaining and the ultimate destination for many heart conditions. Based on scientific evidence, there is a worldwide incremental increase in CIED implantations numbers. OBJECTIVE: Early infection of cardiac implantable electronic devices (CIED)- pacemaker (PM), implantable cardioverter-defibrillator (ICD), and cardiac resynchronization therapy (CRT)- is a growing health challenge. We examined the effectiveness of antibiotic prophylaxis and treatment of early infection of CIED in a single center. METHODS: This is a retrospective, single-center observational study. Data were collected from patients' records from July 2017-July, 2019. All Patients received intravenous ceftriaxone 2gm before incision, Gentamicin 120mg pocket irrigation, and oral Amoxicillin/Clavulanate for 5 days post-implantation. RESULTS: A 639 consecutive CIED implantations - PM (n=474, mean age, 64yr, female=49%), ICD (n=106, mean age 56yr, female=17%) and CRT (n=59, mean age, 54yr, female=20%)- were performed over 3years. The incidence of early infection was 1.9% (12 cases), female=41%. PM=5/474, ICD=5/106, and CRT=2/59. Three out of the 12 patients had total device explant due to pocket abscess; one PM had a generator changed; one ICD who had a pneumothorax, and the third one had reimplantation after ICD lead perforation. Nine cases were managed conservatively using saline dressing and oral Amoxicillin/Clavulanate, 3/9 patients developed a hematoma, 4/9 patients developed purulent suture line infection. None of them had infection recurrence on three months follow up. CONCLUSION: Early infection of CIED is a rare complication with multiple predisposing factors. Our protocol is reassurance and prompt initiation of management protocol to prevent and treat this issue's sequences.
No takes yet. Share an insight, caveat, or question.
Alshoubaki et al. (2021) conducted an observational in Early infection of cardiac implantable electronic devices (CIED) (n=639). Standardized antibiotic prophylaxis protocol (IV ceftriaxone, gentamicin pocket irrigation, and oral amoxicillin/clavulanate) was evaluated on Incidence of early infection (within 28 days). A standardized antibiotic prophylaxis protocol for cardiac implantable electronic device implantation was associated with an early infection incidence of 1.9% (12 of 639 cases).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: