Key result
Vastus lateralis motor unit recruitment thresholds and discharge rates were largely similar across different knee angles during submaximal isometric torque production.
The similar recruitment threshold and discharge behavior of vastus lateralis motor units during submaximal isometric torque production suggests net motor unit activation does not change significantly along the ascending limb of the knee-angle torque relationship.
Net quadriceps activation appears angle-independent during submaximal isometric tasks; extends motor control models but leaves clinical translation open.
Single motor unit electromyographic (EMG) activity of the knee extensors was investigated at different knee angles with subjects (n = 10) exerting the same absolute submaximal isometric torque at each angle. Measurements were made over a 20 degrees range around the optimum angle for torque production (AngleTmax) and, where feasible, over a wider range (50 degrees ). Forty-six vastus lateralis (VL) motor units were recorded at 20.7 +/- 17.9 %maximum voluntary contraction (%MVC) together with the rectified surface EMG (rsEMG) of the superficial VL muscle. Due to the lower maximal torque capacity at positions more flexed and extended than AngleTmax, single motor unit recruitment thresholds were expected to decrease and discharge rates were expected to increase at angles above and below AngleTmax. Unexpectedly, the recruitment threshold was higher (P < 0.05) at knee angles 10 degrees more extended (43.7 +/- 22.2 N.m) and not different (P > 0.05) at knee angles 10 degrees more flexed (35.2 +/- 17.9 N.m) compared with recruitment threshold at AngleTmax (41.8 +/- 21.4 N.m). Also, unexpectedly the discharge rates were similar (P > 0.05) at the three angles: 11.6 +/- 2.2, 11.6 +/- 2.1, and 12.3 +/- 2.1 Hz. Similar angle independent discharge rates were also found for 12 units (n = 5; 7.4 +/- 5.4 %MVC) studied over the wider (50 degrees ) range, while recruitment threshold only decreased at more flexed angles. In conclusion, the similar recruitment threshold and discharge behavior of VL motor units during submaximal isometric torque production suggests that net motor unit activation did not change very much along the ascending limb of the knee-angle torque relationship. Several factors such as length-dependent twitch potentiation, which may contribute to this unexpected aspect of motor control, are discussed.
No takes yet. Share an insight, caveat, or question.
Altenburg et al. (2009) studied this question. Different knee angles vs. Optimum angle for torque production (AngleTmax) was evaluated on Single motor unit recruitment thresholds and discharge rates. Vastus lateralis motor unit recruitment thresholds and discharge rates were largely similar across different knee angles during submaximal isometric torque production.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: