Key result
Delayed distortion of a sutureless aortic valve stent can occur, resulting in paravalvular leakage and increased transvalvular gradients requiring reoperation or balloon dilatation.
Case Report (n=2)
Sutureless aortic valves may present unique surgical risks, including delayed stent distortion leading to paravalvular leakage and increased gradients.
Answers are grounded in this paper and cite their sources.
Clinicians should monitor for late stent distortion after sutureless AVR; this case leaves open questions on incidence and prevention.
In recent years, sutureless aortic valves have grown in popularity. As these valves do not need to be anchored with sutures, shorter cardiac ischaemia and extracorporeal circulation times can potentially be achieved. In addition, the absence of a sewing ring in these valves results in a greater effective orifice area for any given size. Postoperative outcome may be improved using sutureless valves especially when combined with minimally invasive surgical techniques. However, sutureless aortic valves present unique surgical risks. We report 2 cases of delayed distortion of a sutureless aortic valve stent resulting in paravalvular leakage and increased transvalvular gradients. One patient underwent a reoperation with an aortic valve replacement using a standard biological aortic valve, the other patient was treated with balloon dilatation of the aortic valve stent.
No takes yet. Share an insight, caveat, or question.
Fleißner et al. (2014) conducted a case report in Complications of sutureless aortic valve implantation (n=2). Sutureless aortic valve implantation was evaluated on Delayed distortion of a sutureless aortic valve stent. Delayed distortion of a sutureless aortic valve stent can occur, resulting in paravalvular leakage and increased transvalvular gradients requiring reoperation or balloon dilatation.
Synapse has enriched 10 related papers. Consider them for comparative context: