Key result
Novel ECG-PPG emulator accurately reproduces cardiovascular timing with PR interval errors below ~2 ms.
Why the study?
Existing physiological signal emulators often generate ECG or PPG independently and offer limited control over arrhythmia detection and ECG-PPG coupling.
The developed low-cost, open-source physiological signal emulator accurately reproduces synchronized ECG and PPG signals for cardiovascular device calibration and testing.
Answers are grounded in this paper and cite their sources.
May enable standardized device calibration in research labs; leaves open clinical translation and validation.
Physiological signal emulators support the calibration, validation, and stress testing of cardiovascular monitoring devices. However, many existing systems generate electrocardiography (ECG) or photoplethysmography (PPG) independently and offer limited control over arrhythmia detection and ECG–PPG coupling. This study presents a programmable physiological signal emulator that integrates a unified event-driven ECG–PPG model with synchronized multichannel hardware. The model represents atrial pacing, atrioventricular conduction, and ventricular activation as separate functional blocks, enabling normal sinus rhythm, first-degree atrioventricular block, second-degree atrioventricular block Mobitz I, complete atrioventricular block, atrial tachycardia, and ventricular tachycardia. A Gaussian-based ECG is generated from the atrial and ventricular event sequences, while a multi-Gaussian PPG waveform is derived from ventricular activation using a beat-class-dependent electromechanical delay. The same processing architecture supports playback of recorded 12-lead clinical ECG data through an inverse lead transformation. The hardware uses an STM32F407VET6 microcontroller and MCP4921 digital-to-analog converters (DACs) to generate 10 synchronized analog outputs, comprising 09 ECG electrodes and 01 PPG channel. Validation covered physiological timing, analog-chain performance, and end-to-end signal reproduction. PR interval errors relative to a commercial electrocardiograph were 1.23 ms for normal sinus rhythm and 1.66 ms for first-degree atrioventricular block. The measured beat-to-beat PR increment during Mobitz I conduction was 40.02±0.04 ms for a programmed value of 40 ms. At commanded amplitudes of at least 800 mV, both output channels achieved absolute amplitude errors below 0.60%, total harmonic distortion below 1%, and signal-to-noise ratios (SNRs) above 30 dB. Inter-channel R-peak skew remained below the 2 ms sampling interval, and all monitored metrics varied by less than 1.5% during 60 min of continuous operation. Reproduction of a clinical 12-lead recording yielded per-lead R2 values of 0.967–0.986 and a cycle-to-cycle correlation of 0.996. The emulator also reproduced amplitude-dependent bias in automated interval measurements and interpretation labels. These results demonstrate a low-cost, open-source platform for reproducible device calibration, algorithm stress testing, medical training, and physiological signal processing research.
No takes yet. Share an insight, caveat, or question.
Huynh et al. (2026) studied Cardiovascular monitoring device calibration. Programmable ECG-PPG physiological signal emulator vs. Programmed reference values was evaluated on Signal reproduction accuracy (PR interval error, amplitude error, THD, SNR). The programmable ECG-PPG physiological signal emulator accurately reproduced physiological timing and signal morphology, achieving PR interval errors below 1.7 ms and amplitude errors below 0.60%.
Synapse has enriched 10 related papers. Consider them for comparative context: