Key result
Maximal oxygen consumption was not significantly different between the modified Astrand and standard Bruce treadmill protocols in moderately trained runners (51.5 vs 51.3 ml/kg/min).
Why the study?
Does the modified Astrand treadmill protocol elicit a different V(.-)O2max compared to the standard Bruce protocol in moderately trained runners?
RCT (n=30)
Random order
Does the modified Astrand treadmill protocol elicit a different V(.-)O2max compared to the standard Bruce protocol in moderately trained runners?
In moderately trained runners, V(.-)O2max is independent of whether the Bruce or modified Astrand treadmill protocol is used, despite differences in maximum heart rate and ventilation.
Either protocol suffices for VO2max testing in moderately trained runners; confirms equivalence of modified Astrand and Bruce protocols.
In practice, the Bruce protocol is the most commonly used treadmill protocol to assess maximal oxygen consumption (V(.-)O2max). It has been suggested that a running protocol (e.g., Astrand) may elicit a comparatively higher V(.-)O2max and different cardiorespiratory responses when applied to moderately trained runners. Thus, the purpose of this study was to compare V(.-)O2max and other cardiorespiratory responses as elicited by the standard Bruce and a modified Astrand treadmill protocol in moderately trained runners. Fifteen women (age = 21 years, height = 171.5 cm, weight = 63 kg, and body fat = 18%) and 15 men (age = 26 years, height = 177 cm, weight = 72 kg, and body fat = 9%) who were moderately trained runners completed a standard Bruce and modified Astrand protocol (random order), separated by approximately 7 days. Heart rate, Borg ratings of perceived exertion, blood pressure, and pulmonary gas exchange variables were measured during the exercise tests using standard laboratory procedures. This study revealed V(.-)O2max values between the Bruce protocol (51.3 +/- 11.6 ml x kg(-1) x min(-1)) and modified Astrand (51.5 +/- 10.9 ml x kg(-1) x min(-1)) were not significantly different in either the men or the women. However, the Bruce protocol elicited significantly higher maximum treadmill time in men and maximum respiratory exchange ratio (RERmax) and maximum minute ventilation (VEmax) values in both genders. Conversely, the modified Astrand elicited a higher HRmax. These data suggest that V(.-)O2max in both moderately trained men and women runners is independent of treadmill protocol despite differences in HRmax, RERmax, and VEmax.
No takes yet. Share an insight, caveat, or question.
Miller et al. (2007) conducted an RCT in Moderately trained runners (n=30). Modified Astrand treadmill protocol vs. Standard Bruce treadmill protocol was evaluated on Maximal oxygen consumption (VO2max). Maximal oxygen consumption was not significantly different between the modified Astrand and standard Bruce treadmill protocols in moderately trained runners (51.5 vs 51.3 ml/kg/min).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: