Key result
Maximal exercise protocols yield similar peak VO2 and hemodynamics but differ in submaximal gas exchange.
Why the study?
Standardization of exercise testing protocols is lacking despite the established importance of exercise testing.
Do different exercise testing protocols affect respiratory and hemodynamic responses in healthy young men?
Do different exercise testing protocols affect respiratory and hemodynamic responses in healthy young men?
Different exercise testing protocols yield similar peak VO2 and hemodynamic responses, but submaximal respiratory values vary by protocol.
Protocol choice may alter submaximal respiratory and hemodynamic values; leaves open optimal standardization for clinical exercise testing.
Although the importance of exercise testing has been well established, standardization of protocols is lacking. In the current study three protocols were compared with respect to respiratory and hemodynamic variables at submaximal and peak exercise. Fifteen healthy young men underwent three maximal exercise tests using the following protocols: (I) an increase of 30 Watt, every three minutes; (II) an increase of 10 Watt, every minute; (III) a continuous load increase of 10 Watt/min. Respiratory measurements were made of oxygen uptake (VO2), carbon dioxide output (VCO2), minute ventilation (VE) and tidal volume (VT). Hemodynamic measurements were made of ECG, heart rate (HR), blood pressure and stroke volume (SV). The latter variable was measured by means of electrical impedence cardiography (EIC). There were no differences in mean maximum load or peak-VO2 between protocols I, II and III. The course of SV was similar in all protocols, i.e. an increase of about 30% until 100 Watt, with a subsequent stabilization until maximum load. All other hemodynamic measurements were similar in both protocols, too. Significant differences were found in submaximal values of VO2 and VCO2. There were no differences in other gas-exchange variables at any moment during exercise. With respect to the VO2max or the hemodynamic response to exercise, any protocol can be used. For the evaluation of submaximal exercise, the protocol that has been used has to be taken into account. Differences at these levels are not related to differences in hemodynamic responses.
No takes yet. Share an insight, caveat, or question.
Bogaard et al. (1996) studied Healthy (n=15). Three maximal exercise protocols vs. Compared against each other was evaluated on Respiratory and hemodynamic variables at submaximal and peak exercise. Three different maximal exercise protocols showed no differences in mean maximum load, peak-VO2, or hemodynamic responses, but significant differences were found in submaximal VO2 and VCO2.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: