Key result
The robotics-assisted tilt table yielded a significantly lower absolute peak oxygen uptake (2.24 L/min) compared to a cycle ergometer (2.81 L/min) and a treadmill (3.19 L/min).
Why the study?
Does a robotics-assisted tilt table (RATT) provide valid and reliable peak cardiopulmonary performance parameters compared to a cycle ergometer and treadmill in healthy subjects?
Cross-Sectional (n=18)
Single-blind (subjects blinded to test order)
Computer randomization for test order
No
Does a robotics-assisted tilt table (RATT) provide valid and reliable peak cardiopulmonary performance parameters compared to a cycle ergometer and treadmill in healthy subjects?
Answers are grounded in this paper and cite their sources.
The robotics-assisted tilt table is a valid and reliable device for exercise testing, producing highly correlated but lower peak cardiopulmonary parameters compared to standard cycle and treadmill modalities.
Robotics-assisted tilt table (RATT) technology provides body support, cyclical stepping movement and physiological loading. This technology can potentially be used to facilitate the estimation of peak cardiopulmonary performance parameters in patients who have neurological or other problems that may preclude testing on a treadmill or cycle ergometer. The aim of the study was to compare the magnitude of peak cardiopulmonary performance parameters including peak oxygen uptake (VO2peak) and peak heart rate (HRpeak) obtained from a robotics-assisted tilt table (RATT), a cycle ergometer and a treadmill. The strength of correlations between the three devices, test-retest reliability and repeatability were also assessed. Eighteen healthy subjects performed six maximal exercise tests, with two tests on each of the three exercise modalities. Data from the second tests were used for the comparative and correlation analyses. For nine subjects, test-retest reliability and repeatability of VO2peak and HRpeak were assessed. Absolute VO2peak from the RATT, the cycle ergometer and the treadmill was (mean (SD)) 2.2 (0.56), 2.8 (0.80) and 3.2 (0.87) L/min, respectively (p < 0.001). HRpeak from the RATT, the cycle ergometer and the treadmill was 168 (9.5), 179 (7.9) and 184 (6.9) beats/min, respectively (p < 0.001). VO2peak and HRpeak from the RATT vs the cycle ergometer and the RATT vs the treadmill showed strong correlations. Test-retest reliability and repeatability were high for VO2peak and HRpeak for all devices. The results demonstrate that the RATT is a valid and reliable device for exercise testing. There is potential for the RATT to be used in severely impaired subjects who cannot use the standard modalities.
No takes yet. Share an insight, caveat, or question.
Saengsuwan et al. (2015) conducted a cross-sectional in Healthy subjects (n=18). Robotics-assisted tilt table (RATT) vs. Cycle ergometer and treadmill was evaluated on Absolute peak oxygen uptake (VO2peak) in L/min (p=<0.001). The robotics-assisted tilt table yielded a significantly lower absolute peak oxygen uptake (2.24 L/min) compared to a cycle ergometer (2.81 L/min) and a treadmill (3.19 L/min).
Synapse has enriched 10 related papers. Consider them for comparative context: