BackgroundAs one of the important neutron-sensitive scintillators, plastic scintillator has been widely used in applications such as non-destructive testing, reactor monitoring, and nuclear physics.PurposeThis study aims to conduct comparative performance tests between self-developed plastic scintillators (SD-PS) and off-the-shelf EJ-276D plastic scintillators.MethodsFirstly, a testing platform was established using a photomultiplier tube (PMT) and a high-speed digitizer to comparatively evaluate the radiation response performance of ⌀2.54 cm×2.54 cm and ⌀5.08 cm×5.08 cm self-developed right cylindrical plastic scintillators with two different formulations, alongside EJ-276D scintillators of same corresponding sizes. Then, energy calibration was performed for each scintillator using a 137Cs source to determine the relative light output to confirm less than 5% reproducibility of the test method. Finally, a 252Cf fission ionization chamber was employed to assess the neutron-γ discrimination capability of the four plastic scintillators, and each scintillator was also utilized to measure the neutron-γ time-of-flight spectrum of the 252Cf source, from which the Figure of Merit (FoM), relative detection efficiency, timing accuracy, and γ misidentification rate were derived.ResultsThe comparison results indicate that the light yield of the ⌀2.54 cm×2.54 cm SD-PS is comparable to that of the corresponding EJ-276D, with the FoM lower less than 10% at most in the 60~640 keVee energy range and detection efficiency lower by 19%. The ⌀5.08 cm×5.08 cm SD-PS shows a 15% lower light yield compared to the corresponding EJ-276D, with the FoM lower by up to 26% and detection efficiency lower by 25% over the same energy range. The timing accuracies of the ⌀2.54 cm×2.54 cm and ⌀5.08 cm×5.08 cm SD-PS are 0.87 ns and 1.25 ns, respectively, which are superior to those of EJ-276D (1.00 ns and 1.38 ns). For all scintillators, the γ misidentification rate remains below 1% at an energy threshold of 120 keVee.ConclusionsAcross all five evaluated metrics, the ⌀2.54 cm×2.54 cm SD-PS demonstrates overall performance on par with or superior to EJ-276D, confirming the viability of the domestic formulation as a commercial-grade alternative for neutron detection. The ⌀5.08 cm×5.08 cm SD-PS exhibits a consistent performance deficit across light yield, neutron-γ discrimination, and detection efficiency, indicating that further optimization of the large-volume fabrication process is needed.
No takes yet. Share an insight, caveat, or question.
Qin et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: