Dose-area product values for pediatric barium meals, micturating cystourethrography, and intravenous urography were 13% to 86% higher than previously reported results.
Why the study?
What are the dose-area product values in frequently performed complex paediatric radiology examinations compared to previously reported results?
What are the dose-area product values in frequently performed complex paediatric radiology examinations compared to previously reported results?
Dose-area product values in complex pediatric radiology exams are significantly higher than previously reported, highlighting the need for dose reduction procedures.
Mean values of the dose-area product for barium meal, micturating cystourethrography and intravenous urography examinations from three health centres and for four age groups are presented in this study. Values measured are between 13% and 86% higher than results previously reported, which justifies the importance of applying procedures which reduce risks to patients.
No takes yet. Share an insight, caveat, or question.
Vañó et al. (1996) studied this question. Dose-area product values for pediatric barium meals, micturating cystourethrography, and intravenous urography were 13% to 86% higher than previously reported results.