Answers are grounded in this paper and cite their sources.
This work is a discussion paper on the subject trapezoidal stilling basin provided with triangular blocks. Baffle blocks are used in stilling basins to reduce cost and improve the performance of the basin. These blocks are, however, subjected to cavitation damage. The discusser has developed a spatial jump-type basin provided with adverse slope to the basin floor having diverging side walls with straight and curved glacis. Theoretical values of the basin floor slope (β) were determined from continuity and momentum principles. Experimental values of floor slope (βopt.) were found to be slightly more than theoretical ones (β) due to simplified assumptions made in the derivation of equations. Sudden offsets were provided at the basin entry to further reduce the cost.
No takes yet. Share an insight, caveat, or question.
Shibnath Mazumder (2025) studied this question.