A mechatronic device based on magnetic servo levitation (MSL) is proposed for long range and wide bandwidth actuation. The force capability of this type of actuator can be significantly larger than a linear motor or voice-coil actuator of similar dimensions. A novel parametric model of the electromagneto-mechanical coupled system has been developed to describe its behavior over a large range of motion and frequency, as opposed to more conventional attractive force small-perturbation models. It also provides a convenient way of devising a feedback linearizing control scheme that eliminates the need for high biasing currents present in most magnetic bearing systems. This paper presents a feedback-linearized controller coupled with a Kalman filter as a first approach to solve the tracking problem for such an actuator. Good tracking performance have been found both in simulation and experiments.
No takes yet. Share an insight, caveat, or question.
Gutiérrez et al. (1998) studied this question.
Synapse has enriched 2 closely related papers on similar clinical questions. Consider them for comparative context: