Key result
A novel patient-specific 3D model of the aortic valve apparatus including coronary ostia demonstrated variations in leaflet displacement and stress compared to non-coronary models.
Why the study?
Numerical modeling of aortic valve behavior is of growing interest, but patient-specific models derived from 3D transesophageal echocardiography have lacked the left ventricle outflow tract and coronary ostia crucial for proper biomechanical assessment.
Including the left ventricle outflow tract and coronary ostia in 3D TEE-derived models of the aortic valve improves biomechanical simulations by capturing leaflet asymmetry.
May refine aortic valve simulations; hypothesis-generating and requires prospective validation before clinical adoption.
There is an increasing interest in the numerical modeling and simulation of the aortic valve behavior and functioning, on the different stages involved as healthy, stenotic or replacement procedure. As echocardiography is a ubiquitous and economic modality, the geometric model construction based on such images is therefore of major interest. In this paper, a new patient-specific approach for modeling the complete aortic valve apparatus - derived from parameters extracted from 3D transesophageal echocardiographs -that includes for the first time the left ventricle outflow tract and the coronary ostia, both crucial for proper assessment of valve biomechanical behavior, is presented. An innovative method for characterizing coronary pressures from patient-specific clinical data, to be used as boundary conditions for the numerical simulation is also described. Results from experiments were presented to evaluate the novel aspects of the model, that permits to compare the existing models (non-coronary model NCM) and the proposed new coronary model (CM). Variations of displacement and stress on each leaflet prove the need of considering leaflet asymmetry. Computed quantities in the results sections are within the range of physiological data. This permits to conclude that the proposed aortic valve apparatus model of the aortic valve apparatus improves on previous ones by considering this extremely complex structure in greater detail.
No takes yet. Share an insight, caveat, or question.
Loureiro-Ga et al. (2021) studied Aortic valve modeling. Patient-specific 3D model including coronary ostia (CM) vs. Non-coronary model (NCM) was evaluated on Variations of displacement and stress on each leaflet. A novel patient-specific 3D model of the aortic valve apparatus including coronary ostia demonstrated variations in leaflet displacement and stress compared to non-coronary models.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: