Key result
Indirect calorimetry showed a strong correlation with invasive blood-gas based measurements for assessing oxygen uptake during aorto-coronary bypass surgery.
Why the study?
Does indirect calorimetry correlate with invasive blood-gas measurements for assessing metabolic gas exchange during aortocoronary bypass surgery using a double pump system?
Observational (n=7)
Does indirect calorimetry correlate with invasive blood-gas measurements for assessing metabolic gas exchange during aortocoronary bypass surgery using a double pump system?
Indirect calorimetry provides a reliable alternative to invasive blood-gas measurements for monitoring metabolic gas exchange during aortocoronary bypass surgery with a double pump system.
Answers are grounded in this paper and cite their sources.
May support noninvasive monitoring during bypass surgery; hypothesis-generating and requires larger validation before practice change.
Oxygen uptake and carbon dioxide excretion during aorto-coronary bypass surgery were studied in seven patients by indirect calorimetry and compared to blood-gas based measurements. Medium-high dose fentanyl, droperidol and midazolam were used for maintaining anaesthesia. During the period of extracorporeal circulation no external oxygenator was used. Circulation was maintained by two pumps by-passing the left and right heart respectively and the patient's lungs were ventilated with O2/N2 using a Servo 900C ventilator. For indirect calorimetric measurements gas concentrations were analysed by Beckman instruments and gas volumes were measured by the Servo 900C ventilator. Oxygen uptake and carbon dioxide excretion decreased by 31% and 39%, respectively. For invasive measurements during extracorporeal circulation, arterial and venous blood gases and pump flow were used. Using pump flow instead of cardiac output when calculating oxygen uptake circumvented errors in thermodilution measurements. There was a good correlation (r = 0.88) between the invasive and the indirect calorimetric measurements. Further, there was a good correlation between naso-pharyngeal temperature and indirect calorimetric measurements of oxygen uptake (r = 0.87).
No takes yet. Share an insight, caveat, or question.
Svensson et al. (1991) conducted an observational in Aorto-coronary bypass surgery (n=7). Indirect calorimetry vs. Invasive blood-gas based measurements was evaluated on Correlation between invasive and indirect calorimetric measurements (r = 0.88). Indirect calorimetry showed a strong correlation with invasive blood-gas based measurements for assessing oxygen uptake during aorto-coronary bypass surgery.