Key result
Continuous mixed venous saturation (SvO2) monitoring was efficacious in providing continual assessment of patient condition during complex peripheral vascular surgery when arterial monitoring was not feasible.
Why the study?
Does continuous mixed venous saturation (SvO2) monitoring provide efficacious assessment of patient condition during complex peripheral vascular surgery when arterial pressure monitoring is not feasible?
Population
2 patients undergoing complex peripheral vascular surgery where arterial pressure monitoring was not feasible
Design
Case_series
Follow-up
intraoperative
Loading...
May offer SvO2 monitoring option when arterial access is infeasible; leaves open its role pending prospective validation.
Case Report (n=2)
No
Does continuous mixed venous saturation (SvO2) monitoring provide efficacious assessment of patient condition during complex peripheral vascular surgery when arterial pressure monitoring is not feasible?
Continuous mixed venous saturation (SvO2) monitoring may be a useful alternative for intraoperative hemodynamic assessment during complex peripheral vascular surgery when arterial pressure monitoring is unavailable.
A 1999 study conducted a case report in Complex peripheral vascular surgery without feasible arterial pressure monitoring (n=2). Continuous mixed venous saturation (SvO2) monitoring was evaluated on Continual assessment of patients' conditions. Continuous mixed venous saturation (SvO2) monitoring was efficacious in providing continual assessment of patient condition during complex peripheral vascular surgery when arterial monitoring was not feasible.