Key result
Transfemoral TAVI utilizing CoreValve in a patient with a regurgitant failing bioprosthesis and horizontal aortic root was associated with difficulties during implantation and retrieval.
Case Report (n=1)
Transfemoral TAVI for severe aortic regurgitation in patients with a horizontal aortic root can present significant procedural challenges regarding device manipulation and retrieval.
Answers are grounded in this paper and cite their sources.
May warrant caution with CoreValve in horizontal-root valve-in-valve AR; leaves open optimal device and access strategies.
Transcatheter aortic valve implantation (TAVI) emerged to be a viable treatment option for failing bioprosthesis in the aortic position. Transfemoral approach is the most common access route for TAVI and associated with most favorable clinical outcome. However, in the presence of unfavorable aortic root anatomy, TAVI via transfemoral approach provides inadequate support for device manipulation during valve positioning, particularly performed for the indication of severe aortic regurgitation. We report our experience on TAVI utilizing CoreValve for a patient with regurgitant failing bioprosthesis with horizontal aortic root where we encountered difficulties during implantation and retrieval of valve delivery system.
No takes yet. Share an insight, caveat, or question.
Chan et al. (2012) conducted a case report in Regurgitant failing bioprosthesis with horizontal aortic root (n=1). Transfemoral TAVI utilizing CoreValve was evaluated on Difficulties during implantation and retrieval of valve delivery system. Transfemoral TAVI utilizing CoreValve in a patient with a regurgitant failing bioprosthesis and horizontal aortic root was associated with difficulties during implantation and retrieval.
Synapse has enriched 10 related papers. Consider them for comparative context: