Key result
A new feedback control system for left ventricular assist devices, evaluated using simulated data, was shown to be fast and very stable in adjusting pump motor current to physiological demand.
A novel feedback control system for LVADs based on estimating systemic vascular resistance demonstrates fast and stable performance in simulated data.
Premature for LVAD clinical use; leaves open need for in vivo validation of resistance-based control.
A left ventricular assist device (LVAD) is a mechanical pump that helps patients with a heart failure (HF) condition. This pump works in parallel to the ailing heart and provides a continuous flow from the weak left ventricle to the ascending aorta. The current supplied to the pump motor controls the flow of blood. A new feedback control system is developed to automatically adjust the pump motor current to provide the blood flow required by the level of activity of the patient. The systemic vascular resistance (RS) is the only undeterministic variable parameter in a patient-specific model and also a key value that expresses the level of activity of the patient. The rest of the parameters are constants for a patient-specific model. To determine the level of activity of the patient, an inverse problem approach is followed. The output data (pump flow) are observed and using an optimized search technique, the best model to describe such output is selected. Furthermore, the estimated RS is used in another patient-specific cardiovascular model that assumes a healthy heart, to determine the blood flow demand. Once the physiological demand is established, the current supplied to the pump motor of the LVAD can be adjusted to achieve the desired blood flow through the cardiovascular system. This process can be performed automatically in a real-time basis using information that is readily available and thus rendering a high degree of applicability. Results from simulated data show that the feedback control system is fast and very stable.
No takes yet. Share an insight, caveat, or question.
Faragallah et al. (2012) studied Heart failure. Feedback control system for left ventricular assist devices was evaluated on System stability and speed. A new feedback control system for left ventricular assist devices, evaluated using simulated data, was shown to be fast and very stable in adjusting pump motor current to physiological demand.
Synapse has enriched 4 closely related papers on similar clinical questions. Consider them for comparative context: