Experimental apparatus for the measurement of temperature dependence of critical current within a strong magnetic field has been developed. Samples, which are tested by the four probe method are cooled by a Gifford-McMahon (GM) type cryocooler to the lowest temperature of 5 K. The sample holder has a diameter of 70 mm and a height of 70 mm. Transport currents, up to 150 A, are supplied to two samples through Bi-based oxide superconducting current leads. An external magnetic field of up to 15 T, which is applied to the samples perpendicular to the sample axis, is generated by a water cooled single Bitter magnet with a room temperature bore of 82 mm. As a performance test, the critical current properties of a silver clad Bi-based oxide tape have been measured at 5.5 K, 30 K and 50 K within a magnetic field up to 15 T. This experiment has demonstrated the validity of this experimental apparatus.
No takes yet. Share an insight, caveat, or question.
Hasebe et al. (1997) studied this question.
Synapse has enriched 2 closely related papers on similar clinical questions. Consider them for comparative context: