Answers are grounded in this paper and cite their sources.
Problem. Titanium alloys of the VT6 type are the most widely used in medicine. However, these alloys have a number of serious disadvantages: low biochemical and biomechanical compatibility. Goal. The aim is development of a technology for the production of a workpiece for dental prostheses from the Zr-Ti-Nb alloy, as well as comparing its properties with those of the Ti-6Al-4V alloy under the same conditions. Methodology. Smelting of the Zr-Ti-Nb alloy was carried out in a vacuum arc furnace in a water-cooled copper crystallizer using a tungsten electrode. After triple remelting, the resulting ingot with a diameter of 120 mm and a height of 100 mm was used to study the chemical composition and mechanical properties of the alloy. A rod with a diameter of 6 mm was obtained from the ingots by deformation processing. Results. The Zr-Ti-Nb alloy has a strength level close to that of the Ti-6Al-4V alloy, the level of plastic characteristics is at the level of the Ti-6Al-4V alloy, the nature of tensile fracture of the Zr-Ti-Nb alloy is the same as that of the Ti- 6Al-4V, the modulus of normal elasticity of the Zr-Ti-Nb alloy is up to 3 times lower than that of the Ti-6Al-4V alloy. Originality. The work provides the expanded information on the effect of deformation processing on the properties of zirconium alloys of the Zr-Ti-Nb system. Practical value. A technology for the production of a workpiece for dental implants from Zr-Ti-Nb alloy has been developed.
No takes yet. Share an insight, caveat, or question.
Kapustian et al. (2020) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: