Friction of slightly wetted textiles can decrease by lubrication or increase via capillary bridges, yet the controls are unclear. We isolated filament count while fixing polymer (polyamide, PA) and knit structure (double jersey), using Textile specimens #1 (monofilament), #60, and #120 (multifilament). Single-pass friction tests on BK7 glass spanned dry to partially wet states by dosing a water mass, a. Through-glass fluorescence and total internal reflection imaging quantified the area of water contacting the glass ( A int ) distinct from water retained in the textile, and X-ray CT with KI contrast mapped liquid distribution. Specimen #1 showed a monotonic decrease in the dynamic friction coefficient ( μ d ) with increasing a and A int , indicating lubrication. By contrast, #60 and #120 exhibited a bell-shaped μ d – a relation peaking near a ≈ 5 mg; the maximum occurred when A int was ∼ 40–60% of the 100 mm 2 contact window and then declined toward the flooded level. CT revealed water localization in #1 and delocalization around filaments/strings in #60 and #120. These behaviors reflect negative Laplace pressure at capillary bridges, which increases as meniscus height h decreases. Thus, tuning A int and h via filament architecture enables switching between higher- and lower-friction states under slight wetting than a dry condition.
No takes yet. Share an insight, caveat, or question.
Nishi et al. (2026) studied this question.