Key result
Prolonged depression of the low frequency component of arterial pressure in patients on mechanical circulatory assist was associated with poor outcomes, including death in 3 of 4 such patients.
Why the study?
Does power spectral analysis of arterial pressure evaluate autonomic stress and predict prognosis in patients on mechanical circulatory assist?
Observational (n=22)
Does power spectral analysis of arterial pressure evaluate autonomic stress and predict prognosis in patients on mechanical circulatory assist?
Power spectral analysis of systemic blood pressure may offer a useful tool for evaluating autonomic nervous system stress and predicting prognosis in patients with circulatory assist devices.
Answers are grounded in this paper and cite their sources.
May identify high-risk patients on mechanical circulatory assist; leaves open prospective validation of power spectral analysis for autonomic prognosis.
PURPOSE: The power density values of high (HF; 0.15 to 0.4 Hz) and low frequency (LF; 0.04 to 0.15 Hz) components of arterial pressure were adopted for evaluation of stress on the autonomic nervous system of patients supported by mechanical circulatory assist. METHODS: Power spectral analysis (PSA) of arterial pressure signals was carried out, and trends in changes in the spectral components were observed in 12 patients on mechanical circulatory support (IABP and/or PCPS) and without the support (n=10). RESULTS: The normalized LF was depressed initially and increased gradually in both groups of patients except for four patients on mechanical circulatory assist. Three patients among them consequently died. CONCLUSIONS: Depressed LF represented marked stress on ANS and prolongation of the depression was related to poor outcome of patients. PSA of systemic blood pressure offers a reasonable tool for evaluation of stress on the ANS and for prediction of the prognosis of patients with circulatory assist devices.
No takes yet. Share an insight, caveat, or question.
Tsutsui et al. (2001) conducted an observational in Mechanical circulatory assist (n=22). Mechanical circulatory support (IABP and/or PCPS) vs. No mechanical circulatory support was evaluated on Trends in changes in the spectral components (normalized LF) of arterial pressure. Prolonged depression of the low frequency component of arterial pressure in patients on mechanical circulatory assist was associated with poor outcomes, including death in 3 of 4 such patients.
Synapse has enriched 10 related papers. Consider them for comparative context: