Why the study?
Does mechanical circulatory support affect autonomic nervous system activity as measured by arterial pressure variability in patients with severe heart failure?
Observational (n=21)
Does mechanical circulatory support affect autonomic nervous system activity as measured by arterial pressure variability in patients with severe heart failure?
Answers are grounded in this paper and cite their sources.
Power spectral analysis of systemic arterial pressure may help evaluate cardiovascular severity and predict clinical outcomes in patients on mechanical circulatory support.
PURPOSE: For evaluation of the autonomic nervous system (ANS) activity of patients with mechanical circulatory support including LVAD, IABP and PCPS, arterial pressure variability (APV) was examined. APV is the power density values of pressure signals. High frequency (0.15 to 0.4 Hz) and low frequency (0.04 to 0.15 Hz) components of APV are regarded as a function of the autonomic nervous system. METHODS: Arterial pressure signals were acquired every 2 hours at 100 Hz for 6 minutes. Power spectral analysis was carried out, and APV was observed in 18 patients with IABP and/or PCPS. APV was also observed in 3 patients with LVADs (Xemex, Zeon Medical, Japan) before their discharge from ICU for transfer to another hospital for cardiac transplantation. RESULTS: Although the value gradually increased in 18 patients with IABP and/or PCPS, sustained low values of LFAnorm of APV in 6 patients were related to prolonged mechanical support, and 4 patients among them died consequently. The normalized power spectral component with low frequency (LFAnorm) was maintained at relatively high values in 3 patients with LVADs. CONCLUSION: The study results suggest that power spectral analysis of systemic arterial pressure offers a reasonable means for the evaluation of the severity of patient cardiovascular condition and for the prediction of clinical outcome. It also suggested that LVAD support exerts a favorable effect on ANS in patients with severe heart failure before cardiac transplantation.
No takes yet. Share an insight, caveat, or question.
Tsutsui et al. (2004) conducted an observational in Severe heart failure requiring mechanical circulatory support (n=21). Left ventricular assist device (LVAD) support vs. IABP and/or PCPS was evaluated on Normalized power spectral component with low frequency (LFAnorm) of arterial pressure variability.
Synapse has enriched 10 related papers. Consider them for comparative context: