Key result
Quantitative myotonia assessment identified prolonged first handgrip relaxation times in patients with chloride (n=30) and sodium (n=31) channel mutations compared to historical controls.
Why the study?
Does quantitative myotonia assessment (QMA) characterize handgrip myotonia in individuals with non-dystrophic myotonia?
Observational (n=91)
Does quantitative myotonia assessment (QMA) characterize handgrip myotonia in individuals with non-dystrophic myotonia?
Quantitative myotonia assessment provides an automated, non-invasive method to evaluate and differentiate myotonia patterns in non-dystrophic myotonia, which is useful for clinical trial planning.
Answers are grounded in this paper and cite their sources.
QMA offers objective handgrip myotonia assessment in channelopathies; supports validation as trial endpoint but should not yet change practice.
INTRODUCTION: Non-dystrophic myotonia (NDM) is characterized by myotonia without muscle wasting. A standardized quantitative myotonia assessment (QMA) is important for clinical trials. METHODS: Myotonia was assessed in 91 individuals enrolled in a natural history study using a commercially available computerized handgrip myometer and automated software. Average peak force and 90% to 5% relaxation times were compared with historical normal controls studied with identical methods. RESULTS: Thirty subjects had chloride channel mutations, 31 had sodium channel mutations, 6 had DM2 mutations, and 24 had no identified mutation. Chloride channel mutations were associated with prolonged first handgrip relaxation times and warm-up on subsequent handgrips. Sodium channel mutations were associated with prolonged first handgrip relaxation times and paradoxical myotonia or warm-up, depending on underlying mutations. DM2 subjects had normal relaxation times but decreased peak force. Sample size estimates are provided for clinical trial planning. CONCLUSION: QMA is an automated, non-invasive technique for evaluating myotonia in NDM.
No takes yet. Share an insight, caveat, or question.
Statland et al. (2012) conducted an observational in Non-dystrophic myotonia (n=91). Quantitative myotonia assessment (QMA) vs. Historical normal controls was evaluated on Average peak force and 90% to 5% relaxation times. Quantitative myotonia assessment identified prolonged first handgrip relaxation times in patients with chloride (n=30) and sodium (n=31) channel mutations compared to historical controls.