Answers are grounded in this paper and cite their sources.
We present a simple solution to address-at the same time-the issue of spinal perfusion, overload on the left ventricle, and brain perfusion during complex distal arch and descending aortic surgery. It is a modification of a passive Gott shunt that includes an extra 10-mm tube interposed between the side port of the ascending aorta cannula and the left subclavian artery. This technique may represent an extra option for surgeons during complex aortic surgery to maintain satisfactory distal perfusion, to reduce the cardiac load, and to provide adequate perfusion to the brain.
No takes yet. Share an insight, caveat, or question.
Gelsomino et al. (2019) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: