Key result
Real time three-dimensional echocardiography provided detailed anatomical evaluation of a funnel-shaped pannus causing severe obstruction above a mitral prosthetic valve.
Case Report (n=1)
No
Real-time three-dimensional echocardiography provides incremental value in diagnosing the localization and extent of pannus formation in prosthetic valve obstruction.
May aid pannus assessment in prosthetic obstruction; leaves open prospective validation before routine adoption.
Prosthetic valve obstruction due to pannus formation can be a life-threatening complication. We showed that real time three dimensional echocardiography has incremental value in diagnosing pannus localization and extent.
No takes yet. Share an insight, caveat, or question.
Ocaklı et al. (2017) conducted a case report in Prosthetic valve obstruction due to pannus formation (n=1). Real time three-dimensional echocardiography (RT 3D TEE) was evaluated on Diagnosis of pannus localization and extent. Real time three-dimensional echocardiography provided detailed anatomical evaluation of a funnel-shaped pannus causing severe obstruction above a mitral prosthetic valve.