Key result
Among patients with implantable cardioverter-defibrillators, total and delayed recall memory significantly decreased over 12 months (P < .05).
Why the study?
Does cognitive function decline over 12 months in patients with an implantable cardioverter-defibrillator?
Observational (n=115)
Does cognitive function decline over 12 months in patients with an implantable cardioverter-defibrillator?
Patients with implantable cardioverter-defibrillators experience a significant decline in memory over 12 months, suggesting a need for cognitive monitoring.
May warrant cognitive monitoring in ICD patients; leaves open causality and need for confirmatory trials.
BACKGROUND: Patients with implantable cardioverter-defibrillators (ICDs) have decreased cognitive function associated with arrhythmic and/or cardiac disorders, such as ischemic cardiomyopathy. Little is known about changes in cognitive function over time among ICD patients. AIMS: The aim of this study was to evaluate baseline-to-12-month changes in cognitive function in memory (total recall and delayed recall), psychomotor speed, and executive function among ICD patients. METHODS: In this prospective study, 115 (mean [SD] age, 64.83 [9.06] years, 75% mean) and 77 ICD patients completed baseline and 12-month face-to-face interviews, respectively, which included neuropsychological tests to evaluate cognitive function. RESULTS: Patients who completed baseline and 12-month testing had decreased total and delayed recall memory (all P < .05). No significant changes from baseline to 12 months were observed in psychomotor speed (t = 0.33; P = .74) and executive function (t = -1.12; P = .27). Using 1.0 standard deviation or below the mean as a cutoff criterion, 12% to 22% of ICD patients had poor cognitive function over time. Particularly, at baseline, 17 (15%) and 15 (13%) of the 115 patients had poor memory in total and delayed recall, respectively. At 12 months, 12 (16%) and 9 (12%) of the 77 patients had poor memory in total and delayed recall, respectively. CONCLUSIONS: In this sample of patients with ICDs, memory was poor at baseline and decreased over 12 months. Future studies are indicated to determine how this change in memory influences outcomes such as medication adherence.
No takes yet. Share an insight, caveat, or question.
Kim et al. (2013) conducted an observational in Implantable cardioverter-defibrillator (ICD) (n=115). Implantable cardioverter-defibrillator was evaluated on Changes in cognitive function in memory (total recall and delayed recall), psychomotor speed, and executive function (p=<.05). Among patients with implantable cardioverter-defibrillators, total and delayed recall memory significantly decreased over 12 months (P < .05).