Key result
Attended and unattended home BP measurements show comparable diagnostic accuracy but low sensitivity versus 24-hour ABPM.
Why the study?
Community health workers increasingly screen for hypertension in rural sub-Saharan Africa, but the diagnostic accuracy of attended versus unattended automated blood pressure measurement at home had not been compared.
Does attended versus unattended automated blood pressure measurement by community health workers have comparable diagnostic accuracy to 24-hour ambulatory blood pressure monitoring in rural sub-Saharan African adults?
Cross-Sectional (n=1,220)
Index and reference tests blinded to each other
Randomly assigned order of BP measurements
Yes
Does attended versus unattended automated blood pressure measurement by community health workers have comparable diagnostic accuracy to 24-hour ambulatory blood pressure monitoring in rural sub-Saharan African adults?
Attended and unattended automated blood pressure measurements by community health workers have comparable diagnostic accuracy with high specificity but low sensitivity compared to 24-hour ambulatory monitoring, suggesting they are useful for initial screening but require confirmatory testing.
Answers are grounded in this paper and cite their sources.
Attended and unattended measurements show comparable accuracy with high specificity but low sensitivity; supports equivalence but leaves open screening utility pending prospective validation.
Background Community Health Workers (CHWs) are increasingly being involved in screening for hypertension in rural sub-Saharan Africa. However the diagnostic accuracy of CHW-led attended (CHW present during procedure) and unattended (CHW absent) automated blood pressure (BP) in home settings has not been compared. Methods We conducted a cross-sectional, population-based diagnostic accuracy study in two health and demographic surveillance systems in Kenya and The Gambia. A random age-stratified sample of individuals aged ≥ 30 years were included. The index tests were attended and unattended automated BP measurements conducted by CHWs at participants’ homes (AHBP). The reference test, 24-hour ambulatory BP monitoring (ABPM), was also conducted by the CHWs. We applied BP cutoffs derived from the European Society of Hypertension to determine sensitivity, specificity, predictive values and area under receiver operating characteristic curve (AUC). Results We included 1220 participants (659 in Kenya and 561 in The Gambia). The median age was 54 years (interquartile range 43 years, 66 years) and 775 (63.5%) participants were women. Age standardized prevalence of hypertension on 24-hour BP was 25.1% (95% confidence interval 21.7, 28.4) in Kenya and 32.7% (28.8, 36.6) in The Gambia. There was no difference in diagnostic accuracy of attended and unattended measurements. In Kenya, the age-standardized sensitivity of attended AHBP was 59.5% (52.1, 66.9) and 56.1% (48.4, 63.8) for unattended AHBP. In The Gambia, these sensitivities were 42.2% (34.9, 49.5) and 42.2% (35.2, 49.2) respectively. The respective age-standardized specificities were 92.5% (90.2, 94.7) and 92.6% (90.2, 95.0) in Kenya and 93.2% (90.6, 95.9) and 93.3% (90.8, 95.9) in The Gambia. The AUC was 0.76 (0.72, 0.80) and 0.74 (0.70, 0.78) for attended and unattended AHBP in Kenya and, 0.68 (0.64, 0.72) and 0.68 (0.64, 0.71) respectively in The Gambia. Conclusions Attended and unattended AHBP conducted by CHWs had comparable diagnostic accuracy. Both approaches showed high specificity but low sensitivity compared with 24-hour ABPM, suggesting that CHW-led AHBP may serve as an initial community-based screening but should not replace confirmatory BP assessment.
No takes yet. Share an insight, caveat, or question.
Lucinde et al. (2026) conducted a cross-sectional in Hypertension (n=1,220). Attended and unattended automated home blood pressure measurements vs. 24-hour ambulatory blood pressure monitoring (ABPM) was evaluated on Diagnostic accuracy (Area under the receiver operating characteristic curve). Attended and unattended automated home blood pressure measurements conducted by community health workers had comparable diagnostic accuracy but low sensitivity compared to 24-hour ABPM.
Synapse has enriched 10 related papers. Consider them for comparative context: