Key result
Two-visit ASHA blood pressure screening detects hypertension with ~86% sensitivity compared to 24-hour ABPM.
Why the study?
The hypertension screening cascade in India experiences substantial attrition at each referral step. Task-shifting BP measurement to Accredited Social Health Activists (ASHAs) could bypass this attrition, but evidence validating ASHA-measured BP against the gold standard of 24-hour ambulatory blood pressure monitoring (ABPM) was lacking.
Does blood pressure measurement by trained community health workers (ASHAs) using a two-visit protocol accurately detect hypertension compared to 24-hour ambulatory blood pressure monitoring in adults living in urban slums?
Cross-Sectional (n=111)
Yes
Does blood pressure measurement by trained community health workers (ASHAs) using a two-visit protocol accurately detect hypertension compared to 24-hour ambulatory blood pressure monitoring in adults living in urban slums?
Community health workers (ASHAs) using a two-visit digital blood pressure measurement protocol achieve high diagnostic accuracy (89.2%) and substantial agreement (kappa 0.73) against the 24-hour ABPM gold standard, validating task-shifting of community hypertension screening in India while highlighting that single-visit readings should be avoided due to significantly higher false-positive rates.
Answers are grounded in this paper and cite their sources.
Supports task-shifting hypertension screening to ASHAs in urban slums; leaves open need for prospective outcome trials before adoption.
Background & objectives: Hypertension is one of the leading causes of cardiovascular disease in India, yet the screening cascade under the National Programme for Non-Communicable Diseases (NP-NCD) suffers from substantial attrition at each referral step. Task-shifting blood pressure (BP) measurement directly to Accredited Social Health Activists (ASHAs) could bypass this attrition, but evidence validating ASHA-measured BP against ambulatory blood pressure monitoring (ABPM)—the gold standard—is lacking. This study evaluated the diagnostic accuracy of ASHA-measured BP against 24-hour ABPM for hypertension detection in urban slums. Methods In this cross-sectional diagnostic accuracy study, 111 adults (≥ 30 year) from urban slums of Bhopal underwent BP measurement by trained ASHAs using validated digital devices (Omron HEM-7120) following a two-visit protocol, followed by 24-h ABPM (Schiller BR-102 plus). Diagnostic accuracy and agreement (Bland-Altman, Cohen’s kappa, intraclass correlation) were computed against ABPM. Results ABPM-defined hypertension prevalence was 25.2 per cent (28/111). The two-visit ASHA protocol showed sensitivity 85.7 per cent (95% CI: 68.5–94.3), specificity 90.4 per cent (82.1–95.0), positive predictive value 75.0 per cent, negative predictive value 94.9 per cent and Cohen’s kappa 0.73 (substantial agreement). Single readings had significantly more false positives (McNemar P = 0.025). Bland-Altman analysis showed mean systolic BP bias of + 3.1 mmHg (limits of agreement: −18.7 to + 24.8) against 24-h ABPM. White-coat hypertension was 7.2 per cent and masked hypertension 3.6 per cent on two-visit ASHA protocol compared to 24-h ABPM. Interpretation & conclusions: ASHA-measured BP using a two-visit protocol demonstrates good diagnostic accuracy and substantial agreement with ABPM. These findings provide robust evidence that ASHAs can measure blood pressure as reliably as any industry-standard measurement, supporting task-shifting of BP measurement to ASHAs to achieve realistic screening with higher yield and better follow-up of persons with hypertension in the community. Single readings should be avoided due to higher false-positive rates.
No takes yet. Share an insight, caveat, or question.
Lahiri et al. (2026) conducted a cross-sectional in Hypertension (n=111). Two-visit blood pressure measurement by Accredited Social Health Activists (ASHAs) using digital oscillometric devices vs. 24-hour ambulatory blood pressure monitoring (ABPM) was evaluated on Diagnostic accuracy (sensitivity, specificity, and agreement) for hypertension detection against 24-hour ABPM (Sensitivity 85.7%, Specificity 90.4%, Cohen's kappa 0.73, DOR 56.3, 95% CI 68.5-94.3, p=0.025). Two-visit ASHA blood pressure measurement detected hypertension with 85.7% sensitivity, 90.4% specificity, and substantial agreement compared against 24-hour ABPM.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: