Key result
Total root replacement using a stentless Freestyle valve in patients with aortic insufficiency and ascending aortic aneurysm resulted in a 10-year freedom from aortic valve reoperation of 93.4%.
Why the study?
Long-term clinical results needed to be evaluated after Freestyle stentless aortic root bioprosthesis replacement in patients with severe aortic insufficiency and ascending aortic aneurysm.
What are the long-term clinical outcomes of total root replacement using a stentless bioprosthetic valve in patients with severe aortic insufficiency and ascending aortic aneurysm?
Cohort (n=77)
No
What are the long-term clinical outcomes of total root replacement using a stentless bioprosthetic valve in patients with severe aortic insufficiency and ascending aortic aneurysm?
The stentless aortic root bioprosthesis demonstrates excellent long-term durability and survival in patients with severe aortic insufficiency and ascending aortic aneurysm.
Answers are grounded in this paper and cite their sources.
Supports consideration of stentless Freestyle root replacement in selected patients; leaves open need for randomized comparisons.
BACKGROUND: The study is presenting our long-term clinical results after freestyle stentless aortic root bioprosthesis replacement in patients with severe aortic insufficiency with ascending aortic aneurysm. METHODS: Seventy-seven patients with ascending aortic aneurysms and aortic valve insufficiency underwent a total root replacement procedure using a stentless "Freestyle" valve (Medtronic Inc., Minneapolis, Minnesota). There were 50 (64.9%) men and 27 (35.1%) women. Mean age was 68.7 ± 11.1 years. The surgical procedure used a complete root replacement. Concomitant procedures included coronary artery bypass grafting in 15 (19.5%) patients. RESULTS: The mean cardiopulmonary bypass time was 130.3 ± 26.4 minutes and total aortic cross clamp time was 99.5 ± 23.6 minutes. Hospital mortality was 2.6%. The median follow-up time was 11.2 years. The 5- and 10-years freedom from aortic valve reoperation were 97.4 ± 1.2% and 93.4 ± 4.9%, respectively. During 10 years follow up, there were 14 late deaths; 4 deaths were cardiac, and 10 deaths were noncardiac. Valve-related deaths were attributable to thromboembolism in 1 patient, endocarditis in 2 patients, and congestive heart failure in 1 patient. CONCLUSION: The freestyle stentless aortic root bioprosthesis offered good clinical outcomes, in terms of survival and structural valve deterioration. The Freestyle valve is a viable option for use in patients undergoing bioprosthetic aortic valve replacement and expected desire for long-term durability.
No takes yet. Share an insight, caveat, or question.
Ezelsoy et al. (2020) conducted a cohort in severe aortic insufficiency with ascending aortic aneurysm (n=77). Total root replacement using a stentless Freestyle valve was evaluated on 10-year freedom from aortic valve reoperation. Total root replacement using a stentless Freestyle valve in patients with aortic insufficiency and ascending aortic aneurysm resulted in a 10-year freedom from aortic valve reoperation of 93.4%.
Synapse has enriched 10 related papers. Consider them for comparative context: