Key result
AVR with Medtronic Freestyle bioprosthesis shows ~4% operative mortality and good three-year hemodynamics.
Why the study?
Is aortic valve replacement with the Medtronic Freestyle bioprosthesis safe and effective in patients requiring aortic valve replacement?
Observational (n=85)
Is aortic valve replacement with the Medtronic Freestyle bioprosthesis safe and effective in patients requiring aortic valve replacement?
Answers are grounded in this paper and cite their sources.
Aortic valve replacement with the Medtronic Freestyle bioprosthesis demonstrates acceptable safety and good hemodynamic performance, making it a viable option for older patients or those with a small aortic root.
Aim:The purpose of the study was to evaluate the efficacy and safety of aortic valve replacement with medtronic freestyle bioprosthesis.Clinical material and method:The aortic valve was replaced with the medtronic freestyle bioprosthesis in 85 patients.The mean age of patients was 74 years(range,86 88 years).All bioprosthesis were implanted using the freehand subcoronary includes valve replacement technique,which includes removing the aortic sinus from the graft while leaving the non coronary sinus intact.Continuous suture technique was employed.Echocardiogram was performed to evaluate the function of the bioprosthesis during three year follow up.Results:There were four operative deaths with an operative mortality of 3.9%.Postoperative complications developed in 5 patients including central nervous system injury with paresis in 2,transient cerebral ischemia in 2 and upper gastrointestinal tract bleeding in 1.Late deaths occurred in 5 patients(4.7%).ECHO showed good hemodynamic performance of the prosthesis with low mean gradient(6 20mm Hg),and effective valve area(0.9cm 2).The aortic valve was competent or with trifle incompetence by ECHO in 86% of patients one year after operation.Conclusion:These data show that the medtronic freestyle bioprosthesis is an excellent choice for replacement of the aortic valve,especially in patients over the age of 75 years or with small aortic root.
No takes yet. Share an insight, caveat, or question.
Wang et al. (1999) conducted an observational in Aortic valve disease (n=85). Medtronic Freestyle bioprosthesis was evaluated on operative mortality. Aortic valve replacement with the Medtronic Freestyle bioprosthesis resulted in an operative mortality of 3.9% and good hemodynamic performance over a three-year follow-up.