Key result
Medtronic Freestyle and Toronto SPV stentless valves showed no differences in mortality or morbidity in 995 patients, with indexed EOA >1cm2/m2 for all valves up to 3 years postoperatively.
Why the study?
Does the Medtronic Freestyle stentless valve provide different clinical and hemodynamic outcomes compared to the Toronto SPV stentless valve in patients undergoing aortic valve replacement?
Cohort (n=995)
Does the Medtronic Freestyle stentless valve provide different clinical and hemodynamic outcomes compared to the Toronto SPV stentless valve in patients undergoing aortic valve replacement?
Answers are grounded in this paper and cite their sources.
Both the Medtronic Freestyle and Toronto SPV stentless valves offer excellent clinical and hemodynamic results with normalization of LV function up to 3 years post-AVR.
The excellent hemodynamics of stentless valves have been observed by numerous investigators. With the recent release of the Toronto SPV (stentless porcine valve) and the Medtronic Freestyle stentless valves in North America, it is appropriate to now compare the clinical and hemodynamic performance of these devices. We analyzed the results of 995 patients who underwent aortic valve replacement (AVR) with either of the two valves; in all cases a subcoronary implant technique was used. There were important differences in the preoperative characteristics for the two groups: Medtronic Freestyle patients were notably older than the Toronto SPV patients (70.7+/-8.6 vs 61.8+/-11.1 years, p < 0.001) and were markedly more symptomatic (p < 0.0001). In the Toronto SPV group, most patients had New York Heart Association (NYHA) Class II (41.5%) or Class III (44.7%) symptoms preoperatively, while in the Freestyle group, 61.5% were in Class III and 12.5% were in Class IV. There were no notable differences in mortality or morbidity for the two groups. Both devices demonstrated a meaningful decrease in mean gradient and a corresponding increase in effective orifice area (EOA). Furthermore, the indexed EOA (EOA/body surface area [BSA]) was > 1cm2/m2 for all valves indicating there was no patient-prosthetic mismatch. There was a meaningful decrease in left ventricular (LV) mass as well as LV mass index (LVMI) for both devices up to 3 years postoperatively. Our data indicate that there were no differences in clinical outcome or hemodynamic performance of these two valves. Both devices offer excellent results with normalization of LV function.
No takes yet. Share an insight, caveat, or question.
Rizzo et al. (1998) conducted a cohort in Aortic valve replacement (n=995). Medtronic Freestyle stentless valve vs. Toronto SPV stentless valve was evaluated on Mortality, morbidity, and hemodynamic performance. Medtronic Freestyle and Toronto SPV stentless valves showed no differences in mortality or morbidity in 995 patients, with indexed EOA >1cm2/m2 for all valves up to 3 years postoperatively.