Key result
Increasing the fiber volume fraction decreased the maximum principle strain in the tissue-engineered heart valve but led to less closure, while fiber orientation affected strains differently depending on local geometry.
Computational modeling of tissue-engineered heart valves demonstrates that a non-uniform fiber distribution using tailored fiber placement could optimize reinforcement design by balancing strain reduction and valve closure.
Answers are grounded in this paper and cite their sources.
Textile reinforcement may enable aortic use of tissue-engineered valves; leaves open durability and clinical translation pending further validation.
Transcatheter aortic valve implantation of fibrin-based tissue engineered heart valves with a tubular leaflet construct have been developed as an alternative to invasive traditional surgical heart valve implantation. In general, they are well suited for the pulmonary position, but display insufficient mechanical properties for the aortic position. To enable the application of tissue-engineered valves in the systemic circulation, the tissue is reinforced with a textile scaffold. The current study seeks to compare the effect of varying the fiber volume fraction and orientation of bidirectional textile reinforcement on the closed-valve configuration. An anisotropic large deformation material model based on structural tensors was chosen and the materials were characterized. A finite element model was constructed of the heart valve, and the pinching and suturing of the corners along with application of pressure was simulated. Virtual experiments were conducted with fiber volume fractions of 0.1, 0.01, 0.001, and 0.0001 for ±45° fiber orientations. Furthermore, volume fraction was held at 0.01 and fiber orientations of 0°, ±15°, ±30°, ±45°, ±60°, ±75° and 90° from the tube’s axial direction were simulated and compared. It was shown that increasing the fiber volume fraction decreased the maximum principle strain in the valve, but lead to less closure. Additionally, the effect of fiber orientation affected the strains differently at different locations, depending on the local deformed geometry. This indicates that a non-uniform fiber distribution using tailored fiber placement could be used to optimize reinforcement design.
No takes yet. Share an insight, caveat, or question.
Stapleton et al. (2015) studied Valvular heart disease (tissue engineered aortic heart valve). Varying fiber volume fraction and orientation vs. Different volume fractions and orientations was evaluated on Maximum principle strain and valve closure. Increasing the fiber volume fraction decreased the maximum principle strain in the tissue-engineered heart valve but led to less closure, while fiber orientation affected strains differently depending on local geometry.
Synapse has enriched 10 related papers. Consider them for comparative context: