Key result
Semi-rigid prosthetic rings did not affect postoperative left ventricular ejection fraction compared to flexible rings or bands in patients undergoing mitral valve repair.
Why the study?
Does a semi-rigid prosthetic ring improve postoperative left ventricular function compared to a flexible ring or band in patients undergoing mitral valve repair for degenerative mitral regurgitation?
Cohort (n=305)
No
Does a semi-rigid prosthetic ring improve postoperative left ventricular function compared to a flexible ring or band in patients undergoing mitral valve repair for degenerative mitral regurgitation?
Answers are grounded in this paper and cite their sources.
Semi-rigid prosthetic rings do not significantly differ from flexible rings or bands in their impact on postoperative left ventricular function after mitral valve repair.
BACKGROUND: After reports of cardiac impairment caused by mitral annuloplasty with rigid rings, several prosthetic rings with semi-rigidity were introduced. The influence of semi-rigid rings on postoperative cardiac function remains unknown. This study compared postoperative cardiac function between patients receiving a semi-rigid prosthetic ring and those receiving a flexible ring or band. METHODS AND RESULTS: Transthoracic echocardiographic data of 305 patients who underwent mitral valve repair for degenerative mitral regurgitation (227 patients receiving a semi-rigid ring and 78 receiving a flexible ring or band) were retrospectively reviewed. The imbalance in the preoperative characteristics between groups was adjusted with propensity score matching. Left ventricular ejection fraction, end-diastolic dimension, and end-systolic dimension were compared at 1 week, 6 months, and 1 year after surgery. Propensity score matching yielded 68 matched pairs of patients for whom there were few group differences in preoperative covariates. Between patients receiving a semi-rigid ring and those receiving a flexible ring or band in the propensity-matched cohorts, there were no significant differences in ejection fraction (P=0.322), end-diastolic dimension (P=0.576), or end-systolic dimension (P=0.567). CONCLUSIONS: There was little difference in the influence on postoperative cardiac function between semi-rigid rings and flexible rings or bands.
No takes yet. Share an insight, caveat, or question.
Manabe et al. (2013) conducted a cohort in Degenerative mitral regurgitation (n=305). Semi-rigid prosthetic ring vs. Flexible ring or band was evaluated on Left ventricular ejection fraction (EF) over time (MD -1.06, 95% CI -3.17 to 1.05, p=0.322). Semi-rigid prosthetic rings did not affect postoperative left ventricular ejection fraction compared to flexible rings or bands in patients undergoing mitral valve repair.
Synapse has enriched 10 related papers. Consider them for comparative context: