Key result
Female ICD recipients experienced worse quality of life (0.790 vs 0.825) and higher anxiety prevalence (20.5% vs 14.7%, P<0.001) than men, with no significant difference in depression.
Why the study?
Are there gender disparities in symptoms of anxiety, depression, and quality of life among ICD recipients?
Cross-Sectional (n=2,771)
Yes
Are there gender disparities in symptoms of anxiety, depression, and quality of life among ICD recipients?
Absolute Event Rate: 20.5% vs 14.7%
p-value: p=<0.001
While most ICD recipients report good quality of life, female recipients experience significantly worse quality of life and higher rates of anxiety compared to men.
May support sex-specific anxiety screening in ICD recipients; leaves open whether interventions improve outcomes in prospective trials.
BACKGROUND: Most patients cope well with an implantable cardioverter defibrillator (ICD), but psychological distress and ICD-related concerns have been reported in about 20% of ICD recipients. Many previous studies have not distinguished between genders. METHODS: In this nationwide study we compared quality of life, anxiety, and depression symptoms between the genders in ICD recipients, and determined predictors of each of these variables in men and women. All adult Swedish ICD recipients were invited by mail to participate and 2,771 patients (66 ± 12 years) completed standardized measures of quality of life, symptoms of anxiety, and depression. Time since implantation ranged from 1 year to 23 years with a mean of 4.7 ± 3.9. RESULTS: Women reported worse quality of life (mean index 0.790 vs 0.825) and higher prevalence of anxiety (20.5% vs 14.7%) than did men (P < 0.001 for both comparisons), while there were no differences in symptoms of depression (8.8% vs 8.2%). CONCLUSIONS: Most ICD recipients report a good quality of life, without emotional distress, but among the minority with distress, women fare worse than men.
No takes yet. Share an insight, caveat, or question.
Miller et al. (2015) conducted a cross-sectional in Implantable cardioverter defibrillator (ICD) recipients (n=2,771). Female gender vs. Male gender was evaluated on Prevalence of anxiety (p=<0.001). Female ICD recipients experienced worse quality of life (0.790 vs 0.825) and higher anxiety prevalence (20.5% vs 14.7%, P<0.001) than men, with no significant difference in depression.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: