Key result
ASD diameter to LA/RA ratio >2.7 predicts ~6-fold higher odds of BAS in TGA neonates.
Why the study?
Does the echocardiographic ASD diameter/(LA: RA ratio) predict the need for balloon atrial septostomy in neonates with simple transposition of the great arteries?
Observational (n=18)
No
Does the echocardiographic ASD diameter/(LA: RA ratio) predict the need for balloon atrial septostomy in neonates with simple transposition of the great arteries?
The echocardiographic ASD diameter/(LA: RA ratio) is a useful parameter to predict the need for balloon atrial septostomy in neonates with simple transposition of the great arteries.
Answers are grounded in this paper and cite their sources.
Echocardiography remains central for TGA evaluation; leaves open need for prospective validation against advanced imaging.
Transposition of the great arteries is hemodynamically one of the most significant congenital heart diseases. Echocardiography is the most important non-invasive diagnostic tool to evaluate the transposition of great arteries.
No takes yet. Share an insight, caveat, or question.
Öztürk et al. (2022) conducted an observational in Transposition of the Great Arteries (n=18). ASD diameter/(LA: RA ratio) was evaluated on Need for balloon atrial septostomy (BAS) (OR 6.1, 95% CI 2-14.5, p=0.02).
Synapse has enriched 10 related papers. Consider them for comparative context: