Atmospheric water harvesting (AWH) has emerged as a promising decentralized solution, enabling water generation directly from the air without depending on traditional water sources. The aim of present study is to analyze the effect of regeneration temperature and desiccant material quantity on the performance parameters of AWH system. Initially, single-bed configuration with 20 kg of silica gel is tested at regeneration temperatures of 80°C, and 120°C, and later dual-bed system with a total of 40 kg is evaluated to enable alternate sorption and desorption operation. During sorption process, the average ambient temperature and humidity ratio varies between 27.4–27.6°C and 16.1–18.6 g/kg of dry air. The results show that higher regeneration temperatures significantly enhance the desorption rate (0.76–1.52 kg/h) and reduce the desorption time (7 h at 80°C to 4 h at 120°C). With two desiccant beds, the system achieved a water uptake of 302.5 g per kg of desiccant material and a desorption rate of 1.04 kg/h, resulting in a daily water production of 10.4 L/day. The corresponding energy and exergy efficiencies are 26.5% and 6.1%, respectively. These findings demonstrate that increasing both regeneration temperature and desiccant mass significantly improves the water harvesting capability and thermodynamic performance of AWH system.
No takes yet. Share an insight, caveat, or question.
Tiwari et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: