Key result
External loop recording detects AF in acute stroke or TIA with 84% sensitivity versus continuous ECG.
Why the study?
Detection of AF is recommended after ischaemic stroke or TIA, but the diagnostic performance of external loop recording compared with continuous ECG recording required evaluation.
Does external loop recording improve atrial fibrillation detection in patients with acute ischemic stroke or TIA?
Cohort (n=1,412)
Does external loop recording improve atrial fibrillation detection in patients with acute ischemic stroke or TIA?
External loop recording has high specificity but moderate sensitivity and low positive predictive value for AF detection early after stroke, making it unsuitable as a standalone screening tool.
Moderate sensitivity limits external loop recording as standalone AF screening post-stroke; leaves open optimal sequential strategies in larger cohorts.
BACKGROUND: Detection of atrial fibrillation (AF) in patients who had ischaemic stroke and transient ischaemic attack (IS/TIA) is recommended. We aimed to compare external loop recording (ELR) against simultaneous continuous ECG recording for AF detection in patients who had acute IS/TIA and determine sensitivity, specificity and positive predictive value of AF detection using ELR. We hypothesised ELR to detect 15% fewer patients with AF than continuous ECG recording. METHODS: In this prospective cohort study, we included 1412 patients who had acute IS/TIA without prior AF. Monitoring was 48 hours. Primary outcome was AF >30 s. Cardiologist verified AF in continuous ECG was gold standard. RESULTS: In continuous ECG, 38 (2.7%) patients had AF. ELR automatically categorised 219/1412 patients (15.5%) with AF, including 32/38 (85%) patients with AF in continuous ECG. After cardiologist adjudication of ELR recordings, AF was diagnosed in 57/219 patients, of which 32 (56%) had AF in continuous ECG. For adjudicated AF detection by ELR, sensitivity was 84%, 95% CI (69% to 94%), specificity was 98%, 95% CI (97% to 99%) and positive predictive value was 56%, 95% CI (42% to 69%). CONCLUSION: Automatic AF detection with ELR results in an AF diagnosis in more than five patients without AF for each patient with AF as verified in continuous ECG. For adjudicated AF detection by ELR, sensitivity was confirmed to 84% and specificity 98%. Automatic ELR as investigated in this study may be considered to rule out AF, but it is not suitable as a single monitoring device for AF screening in patients early after stroke. TRIAL REGISTRATION NUMBER: NCT02155907.
No takes yet. Share an insight, caveat, or question.
Sejr et al. (2019) conducted a cohort in Acute ischaemic stroke and transient ischaemic attack (n=1,412). External loop recording vs. Simultaneous continuous ECG recording was evaluated on Atrial fibrillation >30 s (Sensitivity 84%, 95% CI 69 to 94). External loop recording for atrial fibrillation detection in patients with acute stroke or TIA demonstrated a sensitivity of 84% (95% CI 69-94%) and specificity of 98% compared to continuous ECG.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: