May 25, 2004Stroke413 citations

Usefulness of Ambulatory 7-Day ECG Monitoring for the Detection of Atrial Fibrillation and Flutter After Acute Stroke and Transient Ischemic Attack

View Full Paper
DJDenis JabaudonUniversity of GenevaJSJuan SztajzelUniversity of GenevaKSK. SievertHôpital Foch

Structured PICO

Does 7-day ambulatory ECG monitoring using an event-loop recording device improve the detection of atrial fibrillation and flutter in patients with acute stroke or TIA compared to standard ECG and 24-hour Holter?

P
Population
149 consecutive patients admitted with acute stroke or transient ischemic attack (TIA). Exclusions: previously documented persistent AF, primary hemorrhagic stroke, or acute large vessel dissection.
I
Intervention
7-day ambulatory ECG monitoring using an event-loop recording (ELR) device
C
Comparator
Standard 12-lead ECG and 24-hour ECG recording (Holter)
O
Outcome
Detection of atrial fibrillation and flutter (AF)surrogate

7-day ambulatory ECG monitoring using an event-loop recorder detects occult atrial fibrillation in an additional 5.7% of stroke/TIA patients who have normal standard ECG and 24-hour Holter recordings.

Abstract

BACKGROUND AND PURPOSE: Although atrial fibrillation is the most frequent cause of cardioembolic stroke, this arrhythmia remains underdiagnosed, as it is often asymptomatic or intermittent and, thus, may not be detected on standard 12-lead ECG or even 24-hour ECG recording (Holter). In this study, we hypothesized that 7-day ambulatory ECG monitoring using an event-loop recording (ELR) device would detect otherwise occult episodes atrial fibrillation and flutter (AF) after acute stroke or transient ischemic attack (TIA). METHODS: One hundred forty-nine consecutive patients admitted to our neurology department with an acute stroke or TIA were systematically screened for emboligenic arrhythmias using standard ECG. In the absence of AF on standard ECG, patients underwent 24-hour ECG recording (Holter), which was followed by a 7-day ambulatory ECG monitoring (ELR) in patients with a normal Holter. Patients with previously documented persistent AF, with primary hemorrhagic stroke, or with acute large vessel dissection were not included in the study. RESULTS: AF was detected in 22 patients. Standard ECG identified AF in 2.7% of the cases at admission (4/149 patients) and in 4.1% of remaining patients within 5 days (6/145). Holter disclosed AF in 5% of patients with a normal standard ECG (7/139 patients), whereas ELR detected AF in 5.7% of patients with a normal standard ECG and normal Holter (5/88 patients). CONCLUSIONS: Following acute stroke or TIA, ELR identified patients with AF, which remained undetected with standard ECG and with Holter. ELR should, therefore, be considered in every patient in whom a cardioembolic mechanism is suspected.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Jabaudon et al. (2004) studied this question.

synapsesocial.com/papers/6a0fbda396ccf432805fc218https://doi.org/10.1161/01.str.0000131269.69502.d9
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Is Ambulatory Electrocardiography Useful in the Evaluation of Patients With Recent Stroke?1995 · 22 citations
  2. 2Cardiac Event Recorders Yield More Diagnoses and Are More Cost-effective than 48-Hour Holter Monitoring in Patients with Palpitations: A Controlled Clinical Trial1996 · 246 citations
  3. 3Low-Dose Amiodarone for Maintenance of Sinus Rhythm After Cardioversion of Atrial Fibrillation or Flutter1992 · 277 citations
  4. 4Classification of subtype of acute ischemic stroke. Definitions for use in a multicenter clinical trial. TOAST. Trial of Org 10172 in Acute Stroke Treatment.1993 · 12,428 citations
  5. 5Tissue Plasminogen Activator for Acute Ischemic Stroke1995 · 11,723 citations