Key result
7-day ECG patch monitoring yields ~2.4-fold higher AF detection post-stroke than 24-hour Holter.
Why the study?
Detecting AF after stroke is challenging due to brief unpredictable episodes, particularly in patients with sinus rhythm on admission ECG. Early initiation of a 7-day cardiac ECG patch may offer higher diagnostic yield and influence clinical practice compared with 24-hour Holter monitoring.
Does 7-day adhesive single-lead cardiac ECG patch monitoring improve the detection of atrial fibrillation ≥30 seconds compared with 24-hour Holter monitoring in patients with recent acute ischemic stroke or transient ischemic attack?
Cohort (n=150)
No
Does 7-day adhesive single-lead cardiac ECG patch monitoring improve the detection of atrial fibrillation ≥30 seconds compared with 24-hour Holter monitoring in patients with recent acute ischemic stroke or transient ischemic attack?
Prolonged 7-day cardiac ECG patch monitoring detects more atrial fibrillation episodes than standard 24-hour Holter monitoring after acute ischemic stroke or TIA, leading to a 1.5-fold increase in anticoagulation prescription.
Answers are grounded in this paper and cite their sources.
May increase post-stroke AF detection with early monitoring; leaves open whether it reduces recurrence without randomized confirmation.
Funding Acknowledgements Type of funding sources: Public grant(s) – National budget only. Main funding source(s): Ministry of Health Malaysia Background Stroke secondary to atrial fibrillation (AF) is common and often associated with higher risk of stroke recurrence. Detection of AF is challenging due to brief unpredictable episodes of AF runs, especially in patients whose admission electrocardiogram (ECG) demonstrates a sinus rhythm. Probability of AF detection may be higher with early initiation of prolonged ECG monitoring. Purpose To compare diagnostic yield of 7-day cardiac ECG patch versus 24-hour Holter monitoring for detecting AF≥30 seconds; to identify predictors of AF in stroke patients; to determine if 7-day cardiac ECG patch results in a change in clinical practice. Methods In this investigator-initiated prospective study with pairwise comparison of 24-hour Holter and 7-day cardiac ECG patch monitoring, 150 patients who were admitted to a tertiary referral centre with acute ischemic stroke (AIS) or transient ischemic attack (TIA) within 1 week, without known AF, and had sinus rhythm in the admission 12-lead ECG were enrolled. Each patient underwent simultaneous 24-hour Holter and 7-day cardiac ECG patch monitoring. Routine transthoracic echocardiography was performed on each patient to assess cardiac function and exclude intracardiac thrombus. Results There were 102 (68.0%) male patients. 12 (8.0%) patients had underlying history of coronary artery disease; 26 (17.3%) had recurrent stroke or TIA. On admission, median NIH Stroke scale was 4; 18 (12.0%) patients had thrombolysis with alteplase. On transthoracic echocardiography, none had intracardiac thrombus. Both Holter and cardiac ECG patch monitoring were initiated simultaneously at median 2 days after index stroke event. Of 150 patients, 17 (11.3%) detected AF ≥30 seconds. Of these 17 patients, 7 (4.7%) had AF detected within the first 24 hours on both Holter and cardiac ECG patch; 10 (6.7%) were detected after 24 hours on cardiac ECG patch only. Number needed to screen to detect one AF was 6. Compliance to 7-day cardiac ECG patch monitoring was 81.3%. There was no significant difference in age among patients with and without AF. Although left atrium (LA) was not found to be dilated in patients with AF, LA volume index was significantly higher (28.3±15.9 vs 21.8±8.5, p=0.018) and LA emptying fraction (LAEF) was significantly lower (38.0%±30.2 vs 52.6%±16.7, p=0.007). The prolonged 7-day cardiac ECG monitoring patch resulted in 1.5-fold increase in prescription of anticoagulation therapy. Conclusions A 7-day cardiac ECG patch monitoring detected more patients with AF ≥30 seconds than 24-hour Holter monitoring and resulted in increase in prescription of anticoagulation therapy. Higher LA volume index and lower LA emptying fraction were predictors of AF in patients with a recent stroke.
No takes yet. Share an insight, caveat, or question.
Foo et al. (2023) conducted a cohort in Acute ischemic stroke (AIS) or transient ischemic attack (TIA) (n=150). 7-day adhesive single-lead cardiac ECG patch monitoring vs. 24-hour Holter monitoring was evaluated on Detection of atrial fibrillation (AF) ≥30 seconds. 7-day cardiac ECG patch monitoring detected AF ≥30 seconds in 11.3% of post-stroke/TIA patients compared with 4.7% using 24-hour Holter monitoring (number needed to screen 6).
Synapse has enriched 10 related papers. Consider them for comparative context: