Key result
Hybrid Convergent ablation achieves ~69% freedom from atrial arrhythmias at 1 year.
Why the study?
Hybrid Convergent ablation combines minimally invasive epicardial and endocardial ablation to achieve more extensive ablation of AF substrate, motivating an evaluation of the safety and effectiveness of contemporary procedures.
What are the pooled effectiveness (freedom from atrial arrhythmias at ≥1 year) and 30-day safety (major adverse event rate) of contemporary Hybrid Convergent ablation in patients with persistent and longstanding persistent atrial fibrillation?
Meta-Analysis (n=551)
Yes
What are the pooled effectiveness (freedom from atrial arrhythmias at ≥1 year) and 30-day safety (major adverse event rate) of contemporary Hybrid Convergent ablation in patients with persistent and longstanding persistent atrial fibrillation?
Contemporary Hybrid Convergent ablation using the fourth-generation EPi-Sense device provides a 69% freedom from atrial arrhythmias (50% off antiarrhythmic drugs) at ≥1 year with a 6% 30-day major adverse event rate and no deaths or atrioesophageal fistulas in patients with predominantly persistent and longstanding persistent AF.
Answers are grounded in this paper and cite their sources.
Supports Hybrid Convergent ablation in persistent AF; extends prior data with contemporary pooled efficacy and safety.
Background: Hybrid Convergent ablation for atrial fibrillation (AF) combines minimally invasive surgical (epicardial) and catheter (endocardial) ablation. The procedural goal is to achieve more extensive, enduring ablation of AF substrate around the pulmonary veins, posterior wall, and vestibule of the posterior wall left atrium. Objective: To perform a systematic review and meta-analysis on safety and effectiveness of contemporary Hybrid Convergent procedures. Methods: PubMed, Embase, and manual searches identified primary research articles on Hybrid Convergent. Inclusion criteria focused on contemporary practices (epicardial ablation device and lesions). Clinical outcomes at 1 year or later follow-up, patient population, procedural details, and major adverse events (MAE) were recorded. Results: Of 249 records, 6 studies (5 observational, 1 randomized controlled trial) including 551 patients were included. Endocardial energy sources included radiofrequency and cryoballoon. Hybrid Convergent ablation was mostly performed in patients with drug-refractory persistent and longstanding persistent AF. Mean preprocedural AF duration ranged between 2 and 5.1 years. Most patients (∼92%) underwent Hybrid Convergent in a single hospitalization. At 1 year follow-up or later, 69% (95% confidence interval [CI]: 61%-78%, n = 523) were free from atrial arrhythmias and 50% (95% CI: 42%-58%, n = 343) were free from atrial arrhythmias off antiarrhythmic drugs. Thirty-day MAE rate was 6% (95% CI: 3%-8%, n = 551). Conclusion: Hybrid Convergent ablation is an effective ablation strategy for persistent and longstanding persistent AF. Contemporary procedural approaches and published strategies aim to mitigate complications reported in early experience and address delayed inflammatory effusions.
No takes yet. Share an insight, caveat, or question.
Shrestha et al. (2022) conducted a meta-analysis in Persistent and longstanding persistent atrial fibrillation (n=551). Hybrid Convergent ablation (minimally invasive epicardial unipolar radiofrequency ablation with EPi-Sense combined with endocardial radiofrequency or cryoballoon catheter ablation) vs. Endocardial radiofrequency catheter ablation alone (in 2 of 6 included studies; 4 studies were single-arm) was evaluated on Freedom from atrial arrhythmias (AF/atrial flutter/atrial tachycardia ≥30 seconds after a 3-month blanking period) irrespective of antiarrhythmic drugs at 1 year or later follow-up (Pooled proportion 69%, 95% CI 61%-78%). Hybrid Convergent ablation achieved a pooled 69% freedom from atrial arrhythmias at ≥1 year with a 6% 30-day major adverse event rate.
Synapse has enriched 10 related papers. Consider them for comparative context: